Thermo-mechanical loading of innovative "Mini-skirt" preparation design versus conventional full-coverage maxillary central incisor preparation design: an in vitro study.
Mohammad Rayyan, Rana Walid Tawil, Dana El Ballouli, Ehab A Farghaly, Radwa Ibrahim Eltahawi, Mohamed B A Badawy, Omar Badran, Omayma Tantawy Said Mohammed,
Department of Fixed Prosthodontics, Faculty of Oral and Dental Medicine, Misr university for science and technology, Giza, Egypt. · , Magrabi health, Magrabi hospital, King Fahed Road, Al Mohamadiah, Riyadh, Saudi Arabia, KSA.
Key points
From the paper's conclusion- Within the limitations of this in vitro study, the MS preparation showed favorable biomechanical performance under simulated thermo-mechanical loading. These findings provide a preclinical rationale for further investigation of the MS design, although long-term clinical studies are required before definitive clinical recommendations can be made.
Abstract
BACKGROUND: Conventional full-coverage anterior crown preparations for zirconia often require substantial enamel and dentine reduction and may concentrate palatal-cervical stresses, risking marginal discrepancy and compromised seal. A conservative "Mini-skirt" (MS) design that positions the palatal finish line coronally (above the cingulum) could preserve tooth structure and enhance adhesive support, but its thermo-mechanical performance under thermal cycling and fatigue loading remains unclear. PURPOSE: To evaluate whether a conservative MS anterior preparation, with a palatal finish line above the cingulum, improves the thermo-mechanical behavior of generation-5 zirconia crowns compared with a conventional full-coverage (CF) design. METHODS: Sixty extracted maxillary central incisors were randomly assigned to MS or CF groups (n = 30). Monolithic 4Y zirconia crowns were CAD/CAM-manufactured, air-abraded and adhesively luted. Specimens were thermocycled 10,000 times between 5 °C and 55 °C, then obliquely loaded at 45° for 1.7 × 10⁶ cycles (50 N, 2 Hz); survivors underwent static fracture testing (0.5 mm·min⁻¹). Marginal gaps were quantified from silicone replicas; failures were classified Grades I-IV (restorable = I-III). Finite-element models (~ 1.3 M elements) reproduced boundary conditions to map stress. RESULTS: The MS preparation endured thermo-mechanical ageing markedly better than CF: 93.3% (28/30) versus 53.3% (16/30) of crowns completed the fatigue protocol (χ² = 9.01, p = 0.003). Post-fatigue, median fracture load increased from 860 N (IQR 780-930 N) in CF to 1,140 N (1,030-1,260 N) in MS (p < 0.05). Mean marginal gap contracted from 112 ± 21 μm to 67 ± 14 μm (40% reduction, p < 0.001). Restorable fractures predominated in MS (83%) but were minority in CF (37%); catastrophic Grade IV failures fell from 63% to 17% (χ² = 13.6, p < 0.001). Finite-element analysis corroborated the laboratory data, showing a 40% drop in peak palatal-cervical von Mises stress (415 to 250 MPa) and parallel reductions in tensile dentine stress and cement-shear hotspots. CONCLUSIONS: Within the limitations of this in vitro study, the MS preparation showed favorable biomechanical performance under simulated thermo-mechanical loading. These findings provide a preclinical rationale for further investigation of the MS design, although long-term clinical studies are required before definitive clinical recommendations can be made.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Performance and Failure Mechanisms of Zirconia‐Based Toughened Ceramic CrownsInternational Journal of Applied Ceramic Technology · 2026
- Biomechanical Performance of Zirconia–Calcium Silicate–Silver Hybrid Dental Crown Under Static and Transient Dynamic Loading: A Finite Element and TOPSIS ‐Based Multi‐Criteria EvaluationJournal of Biomedical Materials Research Part B Applied Biomaterials · 2026
- Fracture resistance of super speed-sintered zirconia crowns after mastication simulation.The Journal of prosthetic dentistry · 2026
- Finite Element Analysis of Stress Distribution in Healthy and Restored Mandibular Molars with Zirconia and Lithium Disilicate Crowns Under Vertical and Oblique Loading.Journal of functional biomaterials · 2026
- Effects of Yttria Content and Margin Design on the Fracture Resistance of Monolithic Zirconia CrownsJournal of Functional Biomaterials · 2026
- Impact of restoration design and material on the mechanical behavior of implant-supported monolithic CAD-CAM single crowns: An in vitro study.Journal of prosthodontic research · 2026