Markerless motion capture-derived sway and sit-to-stand kinematics during routine clinical balance tasks in outpatient rehabilitation: a cross-sectional study.
Mahtab Azhdar, Adalberto Loyola-Sanchez, Daniel Timmermans, Martin Ferguson-Pell
Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, Alberta, Canada. · Division of Physical Medicine and Rehabilitation, Department of Medicine, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Alberta, Canada.
Key points
From the paper's conclusion- Single-camera MMC generated quantitative sway and sit-to-stand kinematic descriptors during routine outpatient tasks. These exploratory findings provide preliminary real-world information on MMC-derived measures and support further investigation using external reference systems.
Abstract
BACKGROUND: Markerless motion capture (MMC) may offer a practical way to quantify movement during routine clinical balance tasks, but descriptive data from real-world outpatient settings remain limited. This study described MMC-derived sway and sit-to-stand kinematics during Romberg and Five-times sit-to-stand (FTSTS) testing in outpatient rehabilitation. METHODS: In this exploratory cross-sectional observational study, adults receiving outpatient rehabilitation for musculoskeletal or neurological conditions (n = 61; mean age 67.8 ± 10.6 years) completed 30-s Romberg testing with eyes open and closed and FTSTS. A single depth-camera MMC system exported time-series kinematics for offline processing. Romberg outcomes included mediolateral (ML) and anteroposterior (AP) sway amplitude and sway speed; FTSTS outcomes included peak rise, sit, lean-forward, and lean-backward speeds. FINDINGS: ML sway speed was higher with eyes closed than eyes open (Z = 3.089, p = 0.002; r ≈ 0.40) and remained significant after Bonferroni correction. No clear eyes-open/eyes-closed differences were observed for ML sway amplitude, AP sway amplitude, or AP sway speed. FTSTS peak speeds showed between-participant variability, with lean-forward and lean-backward speeds more dispersed than rise and sit speeds. Mean (SD) peak rise speed was 0.309 (0.088) m/s, peak sit speed was -0.285 (0.090) m/s, peak lean-forward speed was 0.040 (0.033) m/s, and peak lean-backward speed was -0.043 (0.034) m/s. INTERPRETATION: Single-camera MMC generated quantitative sway and sit-to-stand kinematic descriptors during routine outpatient tasks. These exploratory findings provide preliminary real-world information on MMC-derived measures and support further investigation using external reference systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Markerless motion capture to quantify disability and functional performance in spine patients: a concurrent validity study bridging laboratory biomechanics and clinical practice.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Accuracy of markerless motion capture in assessing sagittal-plane lower limb kinematics during running: a systematic review and meta-analysis.Frontiers in bioengineering and biotechnology · 2026
- Inter-system reliability of markerless motion capture in older hip and knee patients during walking.Frontiers in medical technology · 2026
- AI-Enabled Markerless Motion Capture for Gait Analysis and Rehabilitation: A Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- Quantifying Static Postural Control Impairment after Stroke using Markerless Motion CapturemedRxiv · 2026
- A Reproducible Workflow for Validating Two-Dimensional Color Video-Based Markerless Motion Capture for Automated Physical Performance Scoring in Adult.Journal of visualized experiments : JoVE · 2026