A Reproducible Workflow for Validating Two-Dimensional Color Video-Based Markerless Motion Capture for Automated Physical Performance Scoring in Adult.
Xiaotian Yue, Bo Yu
Department of Rehabilitation, School of International Medical Technology, Shanghai Sanda University. · Orthopaedic Rehabilitation Unit, Department of Rehabilitation Medicine, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine; boyu@shgh.cn.
Key points
From the paper's conclusion- This article describes a reproducible validation workflow for a two-dimensional (2D) red-green-blue (RGB) camera-based markerless motion capture (MMC) application.
Abstract
Physical performance tests such as the 30-s sit-to-stand (30-s STS) test, Timed Up and Go (TUG), standing-balance tasks, the five-times sit-to-stand (5xSTS) test, and gait speed are widely used to quantify functional capacity. This article describes a reproducible validation workflow for a two-dimensional (2D) red-green-blue (RGB) camera-based markerless motion capture (MMC) application. The workflow combines standardized test administration, simultaneous RGB and depth-camera acquisition, independent clinician scoring, an operational tracking-quality rule, independent criterion annotation, test-retest assessment, second-clinician rescoring, and robustness testing under altered acquisition conditions. In a verified pilot implementation involving 15 healthy adults and seven physical-performance tests, 203 of 210 initial planned standard-condition acquisitions before technical replacement were analyzable (96.7%). Application-to-criterion intraclass correlation coefficients (ICCs) ranged from 0.781 to 0.972 across tests; the lower value for side-by-side standing occurred in the setting of restricted between-participant range and ceiling behavior. Stress-condition analyzability was 43/54 (79.6%). These pilot results characterize feasibility, agreement, repeatability, and failure modes; they are not interpreted using a retrospectively imposed binary validation threshold.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of a markerless motion capture app for automated scoring of sit-to-stand, timed up and go, and short physical performance battery tests in adults with chronic diseasePLOS Digital Health · 2026
- AI-Enabled Markerless Motion Capture for Gait Analysis and Rehabilitation: A Narrative Review.Bioengineering (Basel, Switzerland) · 2026
- Markerless motion capture to quantify disability and functional performance in spine patients: a concurrent validity study bridging laboratory biomechanics and clinical practice.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Evaluation and Error Characterization of a Multi-View 3D Markerless Motion Capture System for Human Kinematics.Sensors (Basel, Switzerland) · 2026
- Concurrent Validation of a Multi-Camera Markerless Motion Capture System Against Inertial Sensors for Upper- and Lower-Limb Joint Kinematics.Sensors (Basel, Switzerland) · 2026
- Markerless motion capture-derived sway and sit-to-stand kinematics during routine clinical balance tasks in outpatient rehabilitation: a cross-sectional study.Clinical biomechanics (Bristol, Avon) · 2026