Accuracy of markerless motion capture in assessing sagittal-plane lower limb kinematics during running: a systematic review and meta-analysis.
Ming Gao, Yilin An, Conghua Feng, Zhiyuan Yang, Zhenyang Xu, Dewei Mao, Qinghui Shang, Zhiyuan Sun
Shandong Sport University, Jinan, Shandong, China. · Beijing Sport University, Beijing, China.
Key points
From the paper's conclusion- These findings are specific to the MMC technologies and running conditions evaluated in this review.
Abstract
BACKGROUND: Markerless motion capture (MMC) systems have gained increasing attention in sports science and clinical assessment. However, their accuracy in measuring sagittal-plane lower limb kinematics during running remains unclear. METHODS: A systematic review and meta-analysis was conducted following established guidelines. MEDLINE, Embase, Cochrane Library, Web of Science, and Scopus were searched for studies comparing MMC with marker-based systems (MBSs). Data were analyzed using a random-effects model in R 4.3.3. Risk of bias was assessed using the COSMIN Risk of Bias checklist for measurement error and the Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Analytical Cross-Sectional Studies. Heterogeneity, sensitivity analyses, and publication bias (Egger's and Begg's tests) were also evaluated. Subgroup analyses were conducted to explore potential sources of technical heterogeneity according to sampling frame rate, number of cameras, and running condition. RESULTS: A total of 8 studies were included in this analysis. The pooled root mean square error (RMSE) was 3.84° (95% CI: 2.53-5.15°) for the hip, 4.30° (95% CI: 2.55-6.05°) for the knee, and 3.93° (95% CI: 2.29-5.58°) for the ankle. These findings indicated relatively small measurement errors for sagittal-plane lower limb kinematics, although the magnitude and uncertainty of errors varied across joints. Sensitivity analyses generally supported the robustness of the findings. For knee joint kinematics, funnel plot asymmetry tests did not provide statistically significant evidence of publication bias; however, given the limited number of studies, these findings should be interpreted cautiously. Subgroup analyses indicated that technical characteristics had joint-specific effects on MMC-derived kinematic errors, with no consistent advantage observed for higher frame rates or greater camera numbers. CONCLUSION: The included MMC systems showed relatively small measurement errors for sagittal-plane lower limb kinematics during running. These findings are specific to the MMC technologies and running conditions evaluated in this review.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Markerless motion capture for running: validity and reliability of whole-body, joint, and muscle kinematicsJournal of Biomechanics · 2025
- Validation of View-Specific Markerless Motion Analysis for Lower-Extremity Kinematics After Anterior Cruciate Ligament ReconstructionSensors · 2026
- Markerless Motion Capture in Sport and Exercise: A Systematic Review of Applications, Validity, and ReliabilityApplied Sciences · 2026
- From linear to nonlinear gait measures: validity of a multi-view markerless motion capture systembioRxiv · 2026
- Inter-system reliability of markerless motion capture in older hip and knee patients during walking.Frontiers in medical technology · 2026
- AI-Enabled Markerless Motion Capture for Gait Analysis and Rehabilitation: A Narrative Review.Bioengineering (Basel, Switzerland) · 2026