Development and preliminary validation of an LC-MS/MS method for sunitinib therapeutic drug monitoring using quantitative dried blood spots with a blood-to-plasma conversion formula.

Qiaoqiao Li, Maocai Tang, Tiantian Tang, Jin Zeng, Min Zhang, Xiaoxiao Wang, Wanyi Chen, Lixian Li

Department of Pharmacy, Chongqing University Cancer Hospital, Chongqing 400030, China; State Key Laboratory of Neurology and Oncology Drug Development, China. · Department of Gastrointestinal Cancer Center, Chongqing University Cancer Hospital, Chongqing 400030, China.

Key points

From the paper's conclusion
  • This study developed and preliminarily validated a qDBS-based conversion strategy for SUN TDM. The minimal Hct effect and acceptable agreement in the validation set support further evaluation of qDBS for patient-centric SUN TDM.

Abstract

OBJECTIVES: Conventional venous sampling cannot reliably ensure accurate collection timing, potentially affecting therapeutic drug monitoring (TDM) of sunitinib (SUN). Quantitative dried blood spot (qDBS) sampling offers a patient-centric alternative; however, reliable DBS-to-plasma conversion requires validation. This study therefore aims to develop and preliminarily validate a qDBS-to-plasma conversion formula for SUN TDM. DESIGN & METHODS: A qDBS based method was developed and validated for simultaneous quantification of SUN and its active metabolite N-desethyl sunitinib (SU12662). Analytical validation followed FDA and IATDMCT guidelines. The impact of hematocrit (Hct) on quantification was evaluated. Thirty-eight paired DBS and plasma samples were concentration-stratified and randomly divided into a derivation set (n = 20) and a validation set (n = 18). Passing-Bablok regression was used to establish conversion equations, which were evaluated by Bland-Altman analysis and the EMA ±20% acceptance criterion. RESULTS: The method demonstrated satisfactory analytical performance. Hct-related bias was negligible within 30%-50%, supporting conversion without additional Hct correction. Passing-Bablok regression generated the conversion equations: CDBS = -3.61 + 1.69 × Cpla for SUN and CDBS = -1.42 + 1.70 × Cpla for SU12662. In the validation set, Bland-Altman analysis showed minimal bias between estimated and measured plasma concentrations (SUN: -0.91%; SU12662: 4.58%). The EMA ±20% criterion was met for 14/18 SUN samples (77.8%) and 18/18 SU12662 samples (100%). CONCLUSIONS: This study developed and preliminarily validated a qDBS-based conversion strategy for SUN TDM. The minimal Hct effect and acceptable agreement in the validation set support further evaluation of qDBS for patient-centric SUN TDM.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers