A-344 A therapeutic drug monitoring testing strategy for immunosuppressant drugs from microsampled dried whole blood
Adam Ptolemy, Sami Rifai, Briana Guarino, Sara Pickett, Rafael Garrett, Roy Peake, Mark Kellogg
Key points
From the paper's conclusion- Conclusion Cyclosporine, sirolimus and tacrolimus results from the microsampled dried whole blood TFC-MS/MS testing strategy were accurate relative to traditional analyses of fluid whole blood specimens.
Abstract
Background Therapeutic drug monitoring (TDM) of immunosuppressant drugs (ISD) following solid organ transplantation minimizes a patient’s risk of toxicity and rejection. Frequent blood sampling is required to appropriately quantify drug exposure and adjust dosage. Specimen collection via microsampling represents an emergent alternative to traditional venipuncture. Such minimally invasive techniques permit decentralized or home specimen collections for pediatric patients requiring TDM of ISD. We describe the validation of a volumetric absorptive microsampling (VAMS) testing strategy for the analysis of the ISD cyclosporine, sirolimus and tacrolimus in dried whole blood. Methods 30 µL of fluid whole blood were volumetrically sampled from commercially available calibration standards, quality control (QC) or remnant patient specimens collected by venipuncture and dried on the VAMS tip of the Mitra device (Neoteryx). An ultra-sonication based solvent extraction procedure was optimized to remove the ISD from the dried whole blood. Each were respectively quantified using an established turbulent flow liquid chromatography tandem mass spectrometry (TFC-MS/MS) assay for fluid whole blood ISD testing. Performance of the VAMS strategy was determined through an assessment of linearity, precision, accuracy and the effects of ground transit. Results A 98:2 (v/v) water:methanol extraction solvent provided the highest average recovery for all ISD. Matrix-matched dried external calibration standards (Waters) recovered within 20% of their respective target concentrations (0 to 1500 ng/mL for cyclosporine and 0 to 30 ng/mL sirolimus and tacrolimus). The average calibration curves (N=5) for cyclosporine (R^2: 0.9977, slope: 0.842, intercept: 3.36), sirolimus (R^2: 0.9996, slope: 0.984, intercept: -0.18) and tacrolimus (R^2: 0.9828, slope: 1.007, intercept: -0.03) were linear. The average recovery of dried matrix-matched external QC (N=3 concentrations, BioRad) was 93±13%, 105±4% and 109±7% for cyclosporine, sirolimus and tacrolimus, respectively. Average inter-day (N=20 days) precision (%CV) of the dried external QC was 17.3%, 12.8% and 13.1% for cyclosporine, respectively. Accurate ISD results (N=3) were obtained from dried microsamples of archived College of American Pathology (CAP) proficiency testing material. Dried whole blood specimens were shipped from different locations in Massachusetts to our laboratory for testing. The maximum transit duration, temperature and relative humidity (%RH) ranges experienced were 6 days 19 hours 21 minutes, -8.4 to 22.9°C and 24.7 to 74.8%RH, respectively. All ISD were stable in the microsampled dried whole blood under all shipping conditions, with average concentration biases of 24.0, 0.2 and 0.5 ng/mL for cyclosporine, respectively. Concentrations of ISD derived from paired testing of dried and fluid whole blood (N=30) were highly correlative based on Deming regression: cyclosporine (R: 0.9344, slope: 1.10; bias: 9.9 ng/mL or 5.8%), sirolimus (R: 0.9340; slope: 0.845; bias: 0.1 ng/mL or 1.8%) and tacrolimus (R: 0.9151; slope: 0.0.958; bias: 0.6 ng/mL or 6.2%). Conclusion Cyclosporine, sirolimus and tacrolimus results from the microsampled dried whole blood TFC-MS/MS testing strategy were accurate relative to traditional analyses of fluid whole blood specimens. Testing dried whole blood from home collected specimens may be appropriate for pediatric patients requiring TDM of ISD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reframing immunosuppressant therapeutic drug monitoring: an integrated analytical framework based on microvolume whole blood.Bioanalysis · 2026
- Volumetric Microsampling for Patient-Centric Therapeutic Drug Monitoring in Clinical Pharmacology: A Scoping Review.Journal of clinical pharmacology · 2026
- Assessment of Interpatient and Intrapatient Variability of Dasatinib and Imatinib Concentrations in Patients With Chronic Myeloid Leukemia via Volumetric Absorptive Microsampling at Home.Therapeutic drug monitoring · 2026
- Area Under the Curve-Guided Therapeutic Drug Monitoring of Mycophenolic Acid in Lung Transplant Recipients: Volumetric Absorptive Microsampling and Population Pharmacokinetic-Based Limited Sampling Strategies.The AAPS journal · 2026
- LC-MS/MS quantification of trimethylamine N-oxide in plasma and volumetric absorptive microsamples: analytical validation and feasibility in pediatric kidney transplant recipients.Clinica chimica acta; international journal of clinical chemistry · 2026
- Capillary dried plasma microsampling: A novel approach for therapeutic drug monitoring of tyrosine kinase inhibitors in chronic myeloid leukemia patients by UPLC-MS/MS.Journal of pharmaceutical and biomedical analysis · 2026