Clinical biochemistry

Method optimization and verification of homovanillic acid (HVA), vanillylmandelic acid (VMA) and 5-hydroxyindoleacetic acid (5-HIAA) on liquid chromatography tandem mass spectrometry (LC-MS/MS).

Eley Badr, John Beattie, Joseph Macri, Josko Ivica

Hamilton Regional Laboratory Medicine Program (HRLMP), Hamilton Health Sciences and St. Joseph's Healthcare Hamilton, 237 Barton Street E, Hamilton, ON L8L 2X2, Canada. · Hamilton Regional Laboratory Medicine Program (HRLMP), Hamilton Health Sciences and St. Joseph's Healthcare Hamilton, 237 Barton Street E, Hamilton, ON L8L 2X2, Canada; Department of Pathology and Molecular Medicine, Faculty of Health Sciences, McMaster University, 1280 Main Street W, Hamilton, ON L8S 4L8, Canada.

Key points

From the paper's conclusion
  • We successfully optimized and verified the combination of a Chromsystems kit and laboratory developed method for measuring urinary HVA, VMA and 5-HIAA on our Waters LC-MS/MS.

Abstract

INTRODUCTION: Homovanillic acid (HVA) and vanillylmandelic acid (VMA) are used in diagnosis of neuroblastoma. 5-hydroxyindolacetic acid (5-HIAA) is used in diagnosis of intestinal carcinoid syndrome. The aim of this study is to optimize and verify the Chromsystems kit for these cancer biomarkers on our Waters Xevo TQ-S Cronos LC-MS/MS. MATERIALS AND METHODS: The method was optimized and verified for our LC-MS/MS. The verification included simple (SP) and complex precision (CP), lower limit of detection (LLD) and quantification (LLQ), linearity, carryover, bias through measuring external quality assessment (EQA) samples, and patient comparison with another laboratory that already validated the LC-MS/MS method. RESULTS: For two levels of HVA quality control: SP was 1.3% and 1.8%, CP 4.9% and 3.0%; VMA: SP was 1.5% and 1.3%, CP was 3.5% and 1.6%; and 5-HIAA: SP was 0.7% and 0.9%, CP was 5.4% and 3.8%. The LLD and LLQ were 0.587 μmol/L and 1.20 μmol/L, 0.138 μmol/L and 0.65 μmol/L, and 0.0464 μmol/L and 5.03 μmol/L for HVA, VMA and 5-HIAA, respectively. The linearity was 1.20-290.4 μmol/L (HVA), 0.64-910.7 μmol/L (VMA) and 5.03-1103.4 μmol/L (5-HIAA), without carryover for three analytes. The LC-MS/MS method had no significant bias when compared to the EQA assigned values. The patient comparison had Passing-Bablok regression equations for HVA: y = -0.4801 + 1.153×; VMA: y = -0.3784 + 1.139×; and 5-HIAA: y = 0.0749 + 1.140×. The new reference intervals were adjusted for our method using the method comparison. CONCLUSIONS: We successfully optimized and verified the combination of a Chromsystems kit and laboratory developed method for measuring urinary HVA, VMA and 5-HIAA on our Waters LC-MS/MS.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Method optimization and verification of homovanillic acid (HVA), vanillylmandelic acid (VMA) and 5-hydroxyindoleacetic acid (5-HIAA) on liquid chromatography tandem mass spectrometry (LC-MS/MS) — Science Skim