Simultaneous Quantification of Total Homocysteine and Methylmalonic Acid by LC-MS/MS for Comprehensive Assessment of Vitamin B12 and Folate deficiencies.
Irina Rotaru, Elise Jeannesson, Maryline Schwartz, Jean-Louis Guéant, Rosa-Maria Guéant-Rodriguez
UMR Inserm U954 NGERE (Nutrition-Genetics-Environmental Risks), Team 1, University of Lorraine, Nancy, France; Department of Biochemisty-Molecular Biology and Nutrition, National Reference Laboratory of Inborn Errors of Metabolism - University Regional Hospital of Nancy, France. · Unité DeVAH, University of Lorraine, Nancy, France; Department of Hepato-Gastroenterology, National Center of Inborn Errors of Metabolism - University Regional Hospital of Nancy, France; Cornell Joan Klein Jacobs Center for Precision Nutrition and Health, Cornell University, Ithaca, USA. Electronic address: jpg288@cornell.edu.
Key points
From the paper's conclusion- Here, we present a robust, high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of tHcy and MMA in plasma, urine, and dried blood spots.
Abstract
Vitamin B12 (cobalamin) and folate deficiencies are preventable causes of neurological and hematological disorders, particularly in vulnerable populations. Functional biomarkers such as total homocysteine (tHcy) and methylmalonic acid (MMA) are more sensitive indicators of metabolic impairment than circulating vitamin B12 concentration. However, their simultaneous quantification remains analytically challenging due to chemical diversity and the presence of structurally related endogenous compounds. Here, we present a robust, high-throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of tHcy and MMA in plasma, urine, and dried blood spots. The method employs a simple protein precipitation workflow, efficient disulfide reduction, and optimized chromatographic separation to achieve baseline resolution of MMA and tHcy within a 6-minute run, without derivatization. Validation demonstrated excellent linearity (R2 ≥ 0.999), precision (CV < 5%), and accuracy (bias < ±10%) across physiological and pathological concentration ranges. The lower limits of quantification were 0.78 μmol/L for tHcy and 0.13 μmol/L for MMA, with no significant matrix effects or carry-over. Clinical application in a local reference population (n = 400) confirmed age-dependent tHcy distributions and established an upper MMA reference limit of 0.40 μmol/L, aligning with published thresholds for cobalamin deficiency. This method supports improved detection of functional vitamin B12 deficiency, particularly in resource-limited settings, and has been successfully applied in neonatal screening, clinical research, and fundamental and population studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-337 A Rapid and Selective LC-MS/MS Workflow for Methylmalonic Acid Using Strata™ SE SLEClinical Chemistry · 2026
- Targeted LC-MS/MS Analysis of Malonic Acid Biomarkers in Clinical Laboratory Applications.Advances in experimental medicine and biology · 2026
- B-048 Optimizing vitamin B12 deficiency detection: Evaluation of HoloTC-based reflex strategies to improve diagnostic performance and test utilizationClinical Chemistry · 2026
- Beyond fixed serum vitamin B12 thresholds: A multivariable risk approach to reflex methylmalonic acid testing (NHANES 2011-2014).Clinica chimica acta; international journal of clinical chemistry · 2026
- B-365 Breaking Throughput Barriers: Automated Vitamin D Testing on the Roche Cobas i601 LC-MS/MS in a Tertiary Hospital LaboratoryClinical Chemistry · 2026
- B-291 Vitamin B12 Levels Among Outpatients in Northeast Brazil: A Large-Scale Real-World Data StudyClinical Chemistry · 2026