Scientific reports

Development and validation of dispersive liquid-liquid microextraction coupled with LC-MS/MS for plasma 5-hydroxyindoleacetic acid quantification with application as a biomarker in major depressive disorder.

Saleh I Alaqel, Ayman A Abd Al Maksoud, Ahmed M Aljameeli, Mashael M Alaradi, Mohammed F Aldawsari, Ahmed Serag, Atiah H Almalki

Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Northern Border University, Rafha, 91431, Saudi Arabia. · Department of Psychiatry, Faculty of Medicine, Al-Azhar University, Damietta, Egypt.

Key points

From the paper's conclusion
  • A sensitive dispersive liquid-liquid microextraction (DLLME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for plasma 5-hydroxyindoleacetic acid (5-HIAA) quantification as a depression biomarker.

Abstract

A sensitive dispersive liquid-liquid microextraction (DLLME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for plasma 5-hydroxyindoleacetic acid (5-HIAA) quantification as a depression biomarker. Box-Behnken design evaluated four DLLME factors (disperser volume, extraction volume, pH, centrifugation time) where second-order polynomial model identified optimal conditions with R² = 0.9444, achieving 95.1% extraction recovery. Chromatographic separation employed Poroshell 120 EC-C18 column (2.7 μm, 50 × 3.0 mm) with isocratic elution (20% acetonitrile with 0.1% formic acid) and 5-minute run time. Positive electrospray ionization with multiple reaction monitoring transitions (m/z 192.1 → 146.1 for 5-HIAA; 197.1 → 151.1 for 5-HIAA-d5) enabled selective detection. Validation following ICH M10 guidelines with surrogate matrix calibration demonstrated excellent linearity (r² = 0.9997, 5-1000 ng/mL), adequate sensitivity (LLOQ 5 ng/mL), satisfactory accuracy (-10.3% to + 0.2%) and precision (6.7-14.6% CV), minimal matrix effects (96.8-102.5%), and successful parallelism assessment confirming surrogate-authentic matrix equivalence. Clinical application revealed significantly elevated plasma 5-HIAA in depression (25.73 vs. 17.35 ng/mL, 48% elevation, p < 0.001, Cohen's d = 3.059), strong correlation with Hamilton Depression Rating Scale scores (r = 0.791, r² = 0.625), and excellent diagnostic performance (AUC = 0.985, sensitivity 88.2%, specificity 100%). This validated method demonstrates clinical utility for objective depression assessment combining microextraction sample preparation, sensitive detection, and comprehensive biomarker evaluation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers