Journal of chromatography. A

Ultralow ionic strength pH-gradient cation exchange chromatography for protein separations.

Elahe Naghdi, Müge Bilgen, Wim De Malsche

µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050, Brussels, Belgium. Electronic address: Elaheh.Naghdi@vub.be. · µFlow group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050, Brussels, Belgium.

Key points

From the paper's conclusion
  • In the present study, a pH-gradient CEX method was developed for the first time to separate Hb variants, employing a strong cation exchanger and a simple ultralow ionic strength buffering system.

Abstract

Protein separation has garnered significant attention due to its importance in a variety of fields, particularly in clinical applications. A prominent global example is diabetes diagnosis, which is carried out by measuring long-term blood glucose levels through the quantification of glycated hemoglobin (Hb A1c). Given the complexity of the sample matrix, i.e., blood, and the high probability of interference from other Hb variants, an effective separation step is essential. Salt-gradient cation exchange chromatography (CEX) is currently the predominant charge-based technique for this purpose. An alternative CEX methodology, which relies on an induced pH gradient within the column, offers distinct advantages in terms of resolution and selectivity by focusing analytes into narrow bands. This method has demonstrated a higher degree of compatibility with the purification process and the recently developed vortex chromatography method due to the application of more diluted mobile phases. In the present study, a pH-gradient CEX method was developed for the first time to separate Hb variants, employing a strong cation exchanger and a simple ultralow ionic strength buffering system. The method was systematically optimized with respect to the column and mobile phase properties. A comprehensive investigation of the chromatographic behavior was conducted to provide a profound understanding of the ongoing phenomenon in each stage of the optimization process. The efficacy of the developed method was demonstrated by the successful separation of target analytes at baseline level. Furthermore, the separation mechanism was evaluated based on the experimental findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Ultralow ionic strength pH-gradient cation exchange chromatography for protein separations — Science Skim