Bone

Development and validation of a model using thoracic vertebrae data from low-dose CT scans for detecting AI-QCT-defined lumbar osteoporosis.

Yichi Zhang, Ce Rong, Yanyu Zhang, Zhaohui Wang, Hainan Xiao, Juan Chen, Yao Liang, Xiaoxia Yang,

Department of Endocrinology, Peking University First Hospital, Beijing, China; Clinical Research Institute, Institute of Advanced Clinical Medicine, Peking University, Beijing, China; Key Laboratory of Epidemiology of Major Diseases (Peking University), Ministry of Education, Beijing, China. · iKang Guobin Healthcare Group, Beijing, 100022, China.

Key points

From the paper's conclusion
  • AI-QCT-derived thoracic BMD showed potential for identifying AI-QCT-defined lumbar osteoporosis.

Abstract

Despite evidence supporting opportunistic lumbar osteoporosis screening with low-dose computed tomography (LDCT), a clinically deployable screening strategy is lacking. This study aimed to develop and validate a model using thoracic bone mineral density (BMD) from LDCT for opportunistic screening. This multi-center, cross-sectional study included 18,298 adults who underwent LDCT with coverage from T1 to L2 at 134 Chinese health check-up centers. Outcome was defined as "artificial intelligence quantitative computed tomography (AI-QCT) defined lumbar osteoporosis" based on a mean L1-L2 BMD < 80 mg/cm3 by phantom-less AI-QCT system. Five machine learning models were trained on T1-T12 BMD (n = 11,065) and evaluated internally (n = 4743) and externally (n = 2490). Performance metrics included accuracy, area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value, negative predictive value, Brier score, F1 score and area under the precision-recall curve (AUPRC). AI-QCT-defined lumbar osteoporosis was present in 1730 (9.5%) participants. Higher thoracic BMD was inversely associated with the AI-QCT-defined lumbar osteoporosis. T12 exhibited the strongest association: each 1 mg/cm3 increment reduced odds by 21.9% (OR: 0.781, 95% confidence interval [CI]: 0.769, 0.793, P < 0.001). Logistic regression was selected as the final model. In external validation, it achieved an AUC of 0.993 (95% CI: 0.991, 0.996), AUPRC of 0.922 (95% CI: 0.887, 0.951), F1 score (0.813), sensitivity (0.975), and specificity (0.963). AI-QCT-derived thoracic BMD showed potential for identifying AI-QCT-defined lumbar osteoporosis. Integrating phantomless AI-QCT into lung cancer screening may enable large-scale opportunistic screening, but prospective validation against independent standards is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers