European Spine JournalOpen accessMedicine

Opportunistic osteoporosis screening using CT-based Hounsfield units: a machine learning approach for preoperative spine surgery planning

Akihiko Hiyama, Daisuke Sakai, Hiroyuki Katoh, M. Sato, Masahiko Watanabe

Tokai University

Computational · n=162

Key points

From the paper's conclusion
  • These findings support the clinical utility of HU-based opportunistic screening as a triage approach to prompt confirmatory assessment and perioperative bone health optimization, particularly in settings where DXA is unavailable.

Abstract

PURPOSE: Opportunistic assessment of vertebral bone quality using Hounsfield Units (HU) on preoperative computed tomography (CT) may complement dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. We developed a CT-based framework to predict osteoporosis from HU and basic demographics, restricting model development to cases with consistent HU–DXA agreement (“non-deviant”; residual within ± 1 SD of the axial HU–lowest T-score regression). METHODS: We retrospectively reviewed 162 patients (2018–2025) who underwent lumbar CT and DXA. HU was measured at L1–L4 using axial (three-slice) and sagittal (single-slice) methods; sagittal S1 HU was also obtained. Residual filtering retained 123 non-deviant cases. An XGBoost classifier used 26 features (21 HU measures plus age, sex, height, weight, BMI) and was evaluated in three stratified 80/20 splits (AUC, accuracy, F1, sensitivity, specificity). Feature importance was assessed. RESULTS: In the non-deviant cohort (n = 123), both axial and sagittal HU values showed strong correlations with DXA lowest T-score (ρ = 0.820 and ρ = 0.766, respectively; both p < 0.001). The XGBoost model achieved an average AUC of 0.804 ± 0.067, sensitivity of 0.857 ± 0.143, specificity of 0.759 ± 0.128, accuracy of 0.787 ± 0.061, and F1 score of 0.694 ± 0.048. HU measurements at L3 and L4, sex, body weight, and height were among the top predictive features. CONCLUSIONS: In a carefully selected cohort demonstrating a stable HU–lowest T-score relationship, both axial and sagittal HU measurements demonstrated strong correlations with DXA lowest T-score, supporting their use as surrogate indicators of bone quality. The XGBoost model, trained on CT-derived HU values and demographic data, exhibited moderate classification performance within the non-deviant subset. These findings support the clinical utility of HU-based opportunistic screening as a triage approach to prompt confirmatory assessment and perioperative bone health optimization, particularly in settings where DXA is unavailable. These results represent proof-of-concept performance in HU–DXA–concordant cases and may not generalize to unfiltered populations.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers