Osteoporosis prediction using lumbar CT Hounsfield units: comparative performance and clinical implications of seven machine learning models
Akihiko Hiyama, Daisuke Sakai, Hiroyuki Katoh, M. Sato, Masahiko Watanabe
Tokai University
Key points
From the paper's conclusion- This study aimed to evaluate the utility of L1-L4 average Hounsfield Unit (HU) values from lumbar spine computed tomography (CT) in predicting osteoporosis using multiple machine learning (ML) models.
Abstract
PURPOSE: This study aimed to evaluate the utility of L1-L4 average Hounsfield Unit (HU) values from lumbar spine computed tomography (CT) in predicting osteoporosis using multiple machine learning (ML) models. METHODS: We retrospectively analyzed 172 patients (≥ 50 years) who underwent lumbar spine surgery and received preoperative CT and dual-energy X-ray absorptiometry (DXA) within 3 months. Osteoporosis was defined as a T-score < - 2.5 at either the lumbar spine or femoral neck. The L1-L4 average HU value was used as the sole input variable to develop seven supervised ML models. Model performance was compared using accuracy, precision, recall, F1 score, and area under the receiver operating characteristic curve (AUC), and HU-based thresholds for osteoporosis screening were explored. RESULTS: Of 172 patients, 59 (34.3%) were classified as having osteoporosis. The osteoporosis group showed significantly lower L1-L4 HU values than the non-osteoporosis group (105.1 ± 47.5 vs. 140.1 ± 61.3, p < 0.01). Among the models, K-nearest neighbors (KNN) achieved the most balanced diagnostic performance (accuracy: 0.714 ± 0.048; F1 score: 0.466 ± 0.073). Logistic Regression and Naive Bayes showed the highest AUCs (0.785 ± 0.096 and 0.777 ± 0.098, respectively) but limited recall, whereas Support Vector Machine demonstrated moderate performance. Tree-based models yielded comparatively lower discriminatory ability. Optimal HU ranges for identifying high osteoporosis risk generally converged around 90-130 HU. CONCLUSIONS: ML models using L1-L4 HU values can aid in osteoporosis screening. KNN provided the most robust and balanced diagnostic performance, while Logistic Regression and SVM offered stable threshold-based classification. These findings support the utility of CT-based ML approaches in preoperative spinal surgery settings, particularly where DXA is unavailable or limited.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Opportunistic osteoporosis screening using CT-based Hounsfield units: a machine learning approach for preoperative spine surgery planningEuropean Spine Journal · 2026
- CT Radiomics and Machine Learning for Three-Class Bone Density Classification: An Exploratory Comparison Across Lumbar Vertebral Levels.Tomography (Ann Arbor, Mich.) · 2026
- Artifact-Controlled Multi-Vertebral Transfer Learning Ensemble for Patient-Level Three-Class Osteoporosis Screening Using Thoracoabdominal CT-Derived Lumbar Images.Biomedicines · 2026
- Machine learning-based screening model for osteoporosis in Chinese postmenopausal women: a nationwide study with prospective fracture validation.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2026
- Development and validation of a model using thoracic vertebrae data from low-dose CT scans for detecting AI-QCT-defined lumbar osteoporosis.Bone · 2026
- Routine CT-based hounsfield unit measurements as predictors of osteoporosis: A comparative analysis with DXA and development of a nomogram for clinical application.Medicine · 2026