Departamento de Química Inorgânica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil. · Departamento de Química Analítica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil.

Key points

From the paper's conclusion
  • These findings demonstrate that one-step mAb-AuNP functionalization of fully 3D-printed electrodes provides a rapid, reproducible, and serotype-selective approach to NS1 detection, warranting further validation with clinical samples.

Abstract

Rapid and selective detection of dengue virus serotypes remains challenging because of the co-circulation of antigenically related arboviruses. We developed a fully 3D-printed electrochemical biosensor for dengue virus serotype 2 non-structural protein 1 (DENV-2 NS1). The integrated three-electrode platform incorporated a graphite/polylactic acid working electrode modified in a single drop-casting step with preassembled monoclonal antibody-gold nanoparticle conjugates (mAb-AuNP). DENV-2 NS1 binding was monitored by cyclic voltammetry using [Fe(CN)6]3-/4- as a redox probe; immunocomplex formation partially blocked interfacial electron transfer and decreased the cathodic peak current. The response stabilized after 15 min and was linear from 0.15 to 0.75 μg L-1 (1.75-8.74 pM), with R2 = 0.9922 and a limit of detection of 0.061 μg L-1 (0.71 pM). Three independently prepared biosensors showed a relative standard deviation of 3.4%, indicating good fabrication reproducibility. The immunosensor produced a substantially greater response to DENV-2 NS1 than to DENV-1 NS1, Zika virus NS1, or chikungunya virus E2 protein. In 100-fold-diluted human serum spiked at 0.15 and 0.25 μg L-1, standard-addition analysis yielded recoveries of 106.0 ± 1.3% and 97.7 ± 1.1%, respectively. These findings demonstrate that one-step mAb-AuNP functionalization of fully 3D-printed electrodes provides a rapid, reproducible, and serotype-selective approach to NS1 detection, warranting further validation with clinical samples.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers