A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1.
Dayenny L D'Amato, Natália M Caldas, Lucas V de Faria, Carolina B P Ligiero, Ana Beatriz C Souza, Camille C de Mello, Guilherme P Oliveira, Rafael M Dornellas,
Departamento de Química Inorgânica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil. · Departamento de Química Analítica, Universidade Federal Fluminense, Campus do Valonguinho, Outeiro São João Batista s/n, Centro, Niterói, RJ, 24020-150, Brazil.
Key points
From the paper's conclusion- These findings demonstrate that one-step mAb-AuNP functionalization of fully 3D-printed electrodes provides a rapid, reproducible, and serotype-selective approach to NS1 detection, warranting further validation with clinical samples.
Abstract
Rapid and selective detection of dengue virus serotypes remains challenging because of the co-circulation of antigenically related arboviruses. We developed a fully 3D-printed electrochemical biosensor for dengue virus serotype 2 non-structural protein 1 (DENV-2 NS1). The integrated three-electrode platform incorporated a graphite/polylactic acid working electrode modified in a single drop-casting step with preassembled monoclonal antibody-gold nanoparticle conjugates (mAb-AuNP). DENV-2 NS1 binding was monitored by cyclic voltammetry using [Fe(CN)6]3-/4- as a redox probe; immunocomplex formation partially blocked interfacial electron transfer and decreased the cathodic peak current. The response stabilized after 15 min and was linear from 0.15 to 0.75 μg L-1 (1.75-8.74 pM), with R2 = 0.9922 and a limit of detection of 0.061 μg L-1 (0.71 pM). Three independently prepared biosensors showed a relative standard deviation of 3.4%, indicating good fabrication reproducibility. The immunosensor produced a substantially greater response to DENV-2 NS1 than to DENV-1 NS1, Zika virus NS1, or chikungunya virus E2 protein. In 100-fold-diluted human serum spiked at 0.15 and 0.25 μg L-1, standard-addition analysis yielded recoveries of 106.0 ± 1.3% and 97.7 ± 1.1%, respectively. These findings demonstrate that one-step mAb-AuNP functionalization of fully 3D-printed electrodes provides a rapid, reproducible, and serotype-selective approach to NS1 detection, warranting further validation with clinical samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gold-Enhanced Multielectrode Electrochemical Immunosensor for Rapid Electrochemical Detection of Dengue NS1.ACS omega · 2026
- Laser-Induced Graphene Modified with Gold Nanoparticles for Dengue Biomarker Detection: Toward Portable and Flexible Biosensing Platforms for Early Diagnosis.ACS omega · 2026
- New electrochemical biosensor for the early diagnosis of dengue virus based on a mimetic peptide immobilized on a polymeric nanocomposite.Talanta · 2026
- An Artificial Immune System-Integrated Redox-Capacitive Biosensing Architecture for Dengue NS1 Detection: A Computational Proof of ConceptJ · 2026
- A Novel CRISPR/Cas13a sensor for highly sensitive detection of DENV based on AuPt/g-C3N4@GO and Ag@NU-1000.Biosensors & bioelectronics · 2026
- COMSOL-Based Impedance and Sensitivity Analysis of an Interdigitated Electrode Biosensor for Dengue NS1 Detection.Biosensors · 2026