Laser-Induced Graphene Modified with Gold Nanoparticles for Dengue Biomarker Detection: Toward Portable and Flexible Biosensing Platforms for Early Diagnosis.
Thiago Teixeira da Silva, Isadora Bernardes Sequalini, Evaldo José Corat, Rudimar Riva, Valtencir Zucolotto, Nirton Cristi Silva Vieira
Institute of Science and Technology, Federal University of São Paulo, 12231-280 São José dos Campos, São Paulo, Brazil. · National Institute for Space Research, 12227-010 São José dos Campos, São Paulo, Brazil.
Key points
From the paper's conclusion- These results demonstrate the feasibility of combining porous LIG and AuNPs for electrochemical NS1 detection and provide a basis for the further development of flexible electrochemical biosensors for dengue NS1 detection.
Abstract
Dengue remains a major public health challenge in tropical and subtropical regions, where early detection can support timely clinical management. Nonstructural protein 1 (NS1), released during the acute phase of infection, is an important biomarker for early dengue detection. Here, we report a flexible electrochemical immunosensor based on laser-induced graphene (LIG), a hierarchically porous three-dimensional carbon material produced by laser irradiation of polyimide and functionalized with gold nanoparticles (AuNPs) through a simple electroless deposition process. The incorporation of AuNPs reduced the impedance of the LIG electrode, enhanced interfacial charge transfer, and increased the electrochemically accessible surface area. Structural, morphological, electrochemical, and surface wettability characterizations confirmed the successive modification steps of the sensing platform. The resulting biosensor exhibited a logarithmic response to DENV-2 NS1 over the experimentally evaluated concentration range of 10-1000 ng/mL, with a calculated limit of detection of 3.3 ng/mL. The sensor showed reproducible responses and low cross-reactivity toward Zika virus NS1 under the investigated conditions. These results demonstrate the feasibility of combining porous LIG and AuNPs for electrochemical NS1 detection and provide a basis for the further development of flexible electrochemical biosensors for dengue NS1 detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Gold-Enhanced Multielectrode Electrochemical Immunosensor for Rapid Electrochemical Detection of Dengue NS1.ACS omega · 2026
- A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1.Biosensors & bioelectronics · 2026
- Disposable laser-induced graphene-based biosensor strip for the detection of N-protein using CRISPR activation and ratiometric electrochemical readoutTalanta · 2026
- A Label-Free Graphene Quantum Dot-Based Fluorescent Aptasensor for Rapid and Sensitive Detection of Leptospira interrogans.Journal of fluorescence · 2026
- Bifunctional Laser-Induced Graphene Platforms for Integrated Electrochemical Sensing and Matrix-Free LDI-MS Quantitation of Sarcosine.Analytical chemistry · 2026
- New electrochemical biosensor for the early diagnosis of dengue virus based on a mimetic peptide immobilized on a polymeric nanocomposite.Talanta · 2026