COMSOL-Based Impedance and Sensitivity Analysis of an Interdigitated Electrode Biosensor for Dengue NS1 Detection.
Saleh I Alzahrani
Biomedical Engineering Department, College of Engineering, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31451, Saudi Arabia.
Key points
From the paper's conclusion- These findings demonstrate the potential of computational modeling for characterizing the predicted electrical response of an IDE-based impedimetric NS1 biosensor, providing a basis for sensor optimization and future experimental validation.
Abstract
Dengue remains a major global public health concern, highlighting the need for rapid and sensitive methods for the early detection of dengue virus biomarkers. In the present study, a finite element model for the detection of dengue nonstructural protein 1 (NS1) using an interdigitated electrode (IDE)-based impedimetric biosensor was developed in COMSOL Multiphysics. The proposed sensor consists of gold IDEs coated with an antibody-based biorecognition layer and immersed in a conductive aqueous sample medium. Antibody-NS1 binding was modeled using the Langmuir adsorption isotherm. Frequency-domain simulations were used to examine the impedance response over a range of NS1 concentrations from 0 to 1000 ng/cm3. The results showed that the simulated impedance magnitude decreased with increasing NS1 concentration and excitation frequency. At 10 MHz, the normalized impedance response increased rapidly at low NS1 concentrations and gradually approached saturation at higher concentrations. A linear fit to three simulated concentration points (1-3 ng/cm3) yielded a normalized response slope of 0.9223%/(ng/cm3) (R2 = 0.9963), providing a preliminary characterization of the model-predicted low-concentration response. These findings demonstrate the potential of computational modeling for characterizing the predicted electrical response of an IDE-based impedimetric NS1 biosensor, providing a basis for sensor optimization and future experimental validation. The reported sensitivity and concentration-dependent responses are simulation-based predictions and have not been experimentally validated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Artificial Immune System-Integrated Redox-Capacitive Biosensing Architecture for Dengue NS1 Detection: A Computational Proof of ConceptJ · 2026
- Gold-Enhanced Multielectrode Electrochemical Immunosensor for Rapid Electrochemical Detection of Dengue NS1.ACS omega · 2026
- New electrochemical biosensor for the early diagnosis of dengue virus based on a mimetic peptide immobilized on a polymeric nanocomposite.Talanta · 2026
- A one-step functionalized 3D-printed electrochemical biosensor for serotype-selective detection of dengue NS1.Biosensors & bioelectronics · 2026
- Antibody-detecting resistive biosensor for protein biomarkersMicrosystems & Nanoengineering · 2026
- Label‐Free Electrochemical Impedance Spectroscopy for Biosensing: Evolving Interfaces and Mechanistic InsightsSmall Science · 2025