Electrochemical aptasensor for the detection of placental growth factor protein as a biomarker of preeclampsia using a boron-doped diamond electrode.
Biyas Aurora Nania Nevada, Salma Nur Zakiyyah, Rafa Radithya Swara, Wulan Tri Wahyuni, Qorinah Estiningtyas Sakinah Adnani, Mas Rizky Anggun Adipurna Syamsunarno, Ruri Agung Wahyuono, Isnaini Rahmawati,
Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Padjadjaran, Sumedang, 45363, Indonesia. · Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Padjadjaran, Sumedang, 45363, Indonesia; Study Center of Sensor and Green Chemistry, Faculty of Mathematics and Natural Science, Universitas Padjadjaran, Bandung 40132, Indonesia.
Key points
From the paper's conclusion- These findings demonstrate that the BDD/Au aptasensor is a highly sensitive and selective platform with strong potential for early preeclampsia diagnosis.
Abstract
Preeclampsia is a serious pregnancy complication associated with hypertension and endothelial dysfunction caused by impaired placental vascularization. Early detection is essential to reduce maternal and fetal risks. Placental growth factor (PlGF), a pro-angiogenic biomarker that decreases significantly in preeclampsia, is a promising target for early diagnosis. This study develops a gold-modified boron-doped diamond (BDD/Au) electrochemical aptasensor for sensitive and selective PlGF detection. The selected aptamer is determined based on 3D structure modeling and molecular docking results, followed by electrode fabrication, aptamer immobilization, and characterization using SEM, XPS, CV, EIS, and DPV. The selected aptamer exhibits a docking score of -288.41 and a confidence score of 0.9155. The aptasensor shows a signal-off response, with current decreasing as PlGF concentration increases. It demonstrates excellent linearity (R2 = 0.9952) over 1-10,000 fg/mL, with limits of detection of 2.10 fg/mL in PBS and 2.58 fg/mL in spiked human serum. Selectivity studies against various interfering species show 96.85% selectivity and 83.94% specificity toward PlGF, confirming specific aptamer-target recognition. These findings demonstrate that the BDD/Au aptasensor is a highly sensitive and selective platform with strong potential for early preeclampsia diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A homogeneous electrochemiluminescent sandwich immunosensor based on luminol-functionalized silver nanoparticles and boron nitride quantum dots for sensitive detection of placental growth factor.Analytical methods : advancing methods and applications · 2026
- Design an efficient photoelectrochemical aptasensor for detection of perfluorooctanoic acid based on AuNPs/WO3.Talanta · 2026
- Magnetophoretic gold nanoparticle nanoprobes (AuNPs) and polycarboxylic carbon dot (pCDs) signal amplification enable a fluorometric aptasensor for picomolar progesterone monitoring.Talanta · 2026
- A Real‐Time Antifouling Multivalent Aptamer Platform for Wash‐Free Electrochemical Detection of Low‐Abundance Biomarkers in Human PlasmaAngewandte Chemie International Edition · 2026
- Development of a graphene oxide-based PEGylated fluorescent aptasensor with ultrahigh-sensitivity and anti-fouling properties for the detection of serum carcinoembryonic antigen levels.Mikrochimica acta · 2026
- Real-world discrimination and incremental value of first-trimester placental growth factor for hypertensive disorders of pregnancy: a retrospective Chinese cohort.Frontiers in endocrinology · 2026