Development of a graphene oxide-based PEGylated fluorescent aptasensor with ultrahigh-sensitivity and anti-fouling properties for the detection of serum carcinoembryonic antigen levels.
Qi Feng, Lu Xu, Ding-Fan Guo, Qi Wen, Yun-Hui Liang, Qi Huang, Ting Wang, Kun-He Zhang
Department of Gastroenterology, Jiangxi Provincial Key Laboratory of Digestive Diseases, Jiangxi Clinical Research Center for Gastroenterology, Digestive Disease Hospital, the First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China. · Department of Gastroenterology, Jiangxi Provincial Key Laboratory of Digestive Diseases, Jiangxi Clinical Research Center for Gastroenterology, Digestive Disease Hospital, the First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, China. Tingwang@ncu.edu.cn.
Key points
From the paper's conclusion- Conclusively, this study successfully developed a GO-based P2K-modified fluorescent aptasensor capable of specifically, sensitively, and conveniently detecting CEA levels in clinical serum samples and with potential for clinical application.
Abstract
The specificity and sensitivity of aptamer-based serum biomarker assays can be compromised by nonspecific adsorption of proteins. In this study, we used the carcinoembryonic antigen (CEA) aptamer as a model to develop a fluorescent aptasensor capable of specifically and sensitively detecting serum biomarkers. This aptasensor employs the good antifouling capability of polyethylene glycol 2000 (P2K) to enhance specificity and the good fluorescence resonance energy transfer capability of graphene oxide (GO) to improve sensitivity. The aptasensor was applied to determine pure CEA protein and CEA in clinical serum and demonstrated that the P2K-modified fluorescent aptasensor exhibited significantly superior performance in CEA detection compared with the unmodified aptasensor, including accuracy, precision, linear range, antifouling properties, and selectivity. In the detection of CEA levels in clinical serum samples, the P2K-modified fluorescent aptasensor exhibited a lower limit of detection (LOD) (1.31 vs. 1.90 ng/mL), a wider linear range (1-256 vs. 1-64 ng/mL), better recovery (92.4%-103.6% vs. 73.3%-124.1%), and a smaller relative standard deviation (RSD) (0.7%-2.5% vs. 2.0%-6.4%). The aptasensor is capable of determining CEA levels within 90 min using only 1 µL of serum, with advantages of requiring no prefabrication of sensors, measuring fluorescence intensity in a conventional microplate reader, operating experimentally at room temperature, and high-throughput detection. Conclusively, this study successfully developed a GO-based P2K-modified fluorescent aptasensor capable of specifically, sensitively, and conveniently detecting CEA levels in clinical serum samples and with potential for clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aptamer-enabled surface-imprinted self-assembled monolayer for glycoprotein detection based on the in situ self-assembly of lectin and glucose oxidase for signal amplification.Talanta · 2026
- Integration of computational optics and machine learning for optimized SPR-based carcinoembryonic antigen detectionBiomedical Optics Express · 2026
- Broad-spectrum DNA aptamer for chlorinated organophosphate esters selected by Capture-SELEX and its application in a graphene oxide-based fluorescent aptasensor.Analytical methods : advancing methods and applications · 2026
- An anti-fouling photoelectrochemical-electrochemical sensing platform with a zwitterionic interface and a photocurrent-polarity-switching strategy.Biosensors & bioelectronics · 2026
- Bioinspired fluorinated zwitterionic peptide-based electrochemical biosensors for highly sensitive and antifouling detection of chloramphenicol in food samples.Food chemistry · 2026
- Au/Pt@PEG Nanozymes Probe for Ultrasensitive and Matrix-Robust Lateral Flow Immunoassay of Cardiac Troponin I.Langmuir : the ACS journal of surfaces and colloids · 2026