A Real‐Time Antifouling Multivalent Aptamer Platform for Wash‐Free Electrochemical Detection of Low‐Abundance Biomarkers in Human Plasma
Payel Sen, Survanshu Saxena, Zijie Zhang, Navreen Sandhu, Pranati Das, Jimmy Gu, Todd Hoare, Yingfu Li,
Indian Institute of Technology Tirupati · McMaster University
Key points
From the paper's conclusion- Here, we introduce the Real‐Time Magnetic Multivalent Aptamer (RT‐MagMAp) assay, a one‐pot, wash‐free electrochemical platform that detects the low‐abundance biomarker VEGF 165 directly in diluted human plasma.
Abstract
ABSTRACT Sensitive and specific detection of low‐abundance proteins in complex biofluids is essential for early disease diagnosis and real‐time health monitoring. Electrochemical aptamer‐based biosensors offer rapid, point‐of‐care potential, but their clinical translation has been limited by biofouling, matrix variability, and signal instability in samples such as human plasma. Here, we introduce the Real‐Time Magnetic Multivalent Aptamer (RT‐MagMAp) assay, a one‐pot, wash‐free electrochemical platform that detects the low‐abundance biomarker VEGF 165 directly in diluted human plasma. The RT‐MagMAp system integrates three enabling chemical designs: (i) a hierarchical multivalent aptamer architecture combining bead‐immobilized monomeric aptamers with electrode‐bound trimeric aptamers to form highly stable electroactive sandwich assemblies; (ii) antifouling zwitterionic polymer coatings that house trimeric aptamers while suppressing nonspecific adsorption; and (iii) a dynamic internal calibration mechanism using nonfunctional mutant aptamers to correct for plasma‐dependent variability. Together, these elements enable femtomolar VEGF 165 detection (32–354 fM, depending on calibration method) and quantitative performance across 124 blinded plasma samples, achieving a Pearson correlation coefficient of 1.00 and a concordance correlation coefficient of 0.996 relative to a commercial ELISA. Together, these results establish RT‐MagMAp as a robust, clinically relevant electrochemical platform capable of quantitative, wash‐free protein detection directly in complex biological fluids.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Personalized Cancer-Specific Protein-Aptamer Corona for Orthogonal Multiplex Cancer DiagnosisJournal of the American Chemical Society · 2025
- Mixed Charge Monolayers Enable Multi-Week Continuous Analyte Monitoring in Whole SerumACS Sensors · 2026
- Phase-transited BSA and cyclic-peptide antifouling interface for ultrasensitive PD-L1 detection in undiluted serum.Biosensors & bioelectronics · 2026
- Super-antifouling electrochemical biosensor based on a biomimetic gemini zwitterionic interface for sensitive detection of therapeutic antibodies.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- One-Step Self-Assembling Lipopolymer Coatings Enable Direct Longitudinal Biosensing in Native Biological MatricesarXiv · 2026
- Automated all-in-one device for handling Magnetic Bead-Based Samples in immunoassays.Device · 2026