From the paper's conclusion
  • Seventy-two respondents completed the survey; 61% were board-certified neurosurgeons, and 76% worked in academic hospitals. Confidence varied across the two clinical scenarios. Confidence for MRI-based spinal decision-making was moderate (median 3, IQR 3-4), whereas confidence in X-ray-based sCT for cranial applications was lower (median 2, IQR 2-3). Clinical and external validation were frequently selected as factors supporting confidence, whereas hallucinations and lack of validation limited confidence.

Abstract

INTRODUCTION: Neurosurgery relies heavily on imaging for diagnostic, planning, intra-operative decision-making, and image-guided interventions. Machine learning (ML) enables synthetic imaging, such as synthetic CT (sCT) generated from MRI or biplanar X-rays, potentially reducing radiation exposure and improving imaging access. However, clinicians' confidence in synthetic imaging remains poorly understood. RESEARCH QUESTION: This study assessed respondents attitudes towards synthetic neuroimaging. MATERIAL AND METHODS: An international cross-sectional survey was distributed via the European Association of Neurosurgical Societies (EANS) and a global neurosurgeon database. Nineteen questions covered demographics, general attitudes, and two algorithms: MRI-based sCT, and biplanar X-ray-based sCT. Confidence was reported using a 5-point Likert scale (1 = not confident, 5 = completely confident). Responses were summarized using medians, interquartile ranges (IQR), counts, and percentages. RESULTS: Seventy-two respondents completed the survey; 61% were board-certified neurosurgeons, and 76% worked in academic hospitals. Confidence varied across the two clinical scenarios. Confidence for MRI-based spinal decision-making was moderate (median 3, IQR 3-4), whereas confidence in X-ray-based sCT for cranial applications was lower (median 2, IQR 2-3). Clinical and external validation were frequently selected as factors supporting confidence, whereas hallucinations and lack of validation limited confidence. DISCUSSION AND CONCLUSION: Confidence in synthetic neuroimaging varied across clinical scenarios. Differences may reflect clinical context, perceived consequences of error, input modality, and information provided in each scenario. While synthetic imaging may improve access, reduce radiation exposure, and support decision-making, adoption requires robust, application-specific validation. These findings guide future implementation of synthetic imaging in neurosurgery.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers