Performance of MRI-based synthetic CT for detecting spinal new bone formation in patients with inflammatory arthritis and healthy controls: a comparison with MRI, CT, and radiography.
Simone Tromborg Willesen, Jakob M Møller, Kasper K Gosvig, Susanne Juhl Pedersen, Anna E F Hadsbjerg, Stylianos Georgiadis, Mikkel Østergaard
Copenhagen Center for Arthritis Research, Center for Rheumatology and Spine Diseases, Rigshospitalet, Glostrup, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark; Department of Radiology, Copenhagen University Hospital at Herlev Gentofte, Copenhagen, Denmark. Electronic address: simone.willesen@regionh.dk. · Department of Radiology, Copenhagen University Hospital at Herlev Gentofte, Copenhagen, Denmark.
Key points
From the paper's conclusion- Using ldCT as a reference standard, sCT demonstrated substantially higher sensitivity than T1wMRI and radiography. Intra- and inter-reader reliability and inter-modality agreement between ldCT and sCT were comparable, suggesting that discrepancies in lesion detection primarily reflect reader variability rather than inter-modality differences.
Abstract
OBJECTIVES: This study aims to compare magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT), T1-weighted magnetic resonance imaging (T1wMRI), low-dose CT (ldCT), and radiography for detecting spinal new bone formation (NBF) in participants with axial spondyloarthritis (axSpA), psoriatic arthritis (PsA), rheumatoid arthritis (RA) and healthy controls (HCs). METHODS: All participants underwent whole-spine ldCT and MRI in addition to cervical/lumbar spine radiography (not HCs). sCT was reconstructed using BoneMRI. Images were independently assessed for NBF by 2 readers blinded to other imaging and clinical information. One reader repeated ldCT and sCT reads after 6 months. Sensitivity and specificity were calculated using ldCT as the reference standard. Inter-reader and intra-reader reliability were assessed using intraclass correlation coefficient (ICC) and Cohen's kappa. RESULTS: Sixty-nine participants (36 males, mean age 51.4 years) were included: 30 axSpA, 19 PsA, 10 RA, and 10 HCs. The mean number of NBFs per participant was 25.8 on ldCT, 24.0 on sCT, 9.3 on T1wMRI, and 6.9 on radiography. Sensitivity for NBF detection was highest for sCT (70%), followed by radiography (50% cervical/lumbar and 21% whole-spine) and T1wMRI (28%); specificity was ≥93% across modalities. Inter-reader reliability was high for sCT and ldCT (excellent ICCs, substantial kappas), whereas radiography and T1wMRI showed good ICCs with substantial/moderate kappas. Intra-reader reliability and inter-modality agreement for sCT and ldCT were excellent/substantial (ICCs/kappas). CONCLUSIONS: Using ldCT as a reference standard, sCT demonstrated substantially higher sensitivity than T1wMRI and radiography. Intra- and inter-reader reliability and inter-modality agreement between ldCT and sCT were comparable, suggesting that discrepancies in lesion detection primarily reflect reader variability rather than inter-modality differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning-based synthetic CT for the assessment of spinal structural lesions in axial spondyloarthritis.Skeletal radiology · 2026
- Clinicians' confidence in synthetic neuroimaging: a survey from the EANS emerging Technologies and Innovations in Neurosurgery (ETIN) taskforce.Brain & spine · 2026
- MRI-Based Synthetic CT Shows Promise as a Radiation-Free Alternative to Conventional CT in OrthopaedicsJournal of Bone and Joint Surgery · 2026
- Assessment of Magnetic Resonance Imaging-Derived Synthetic Computed Tomography for Otologic Surgical Planning.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Imaging pathways in spondyloarthritis: integrating radiography, ultrasonography, magnetic resonance imaging, low-dose computed tomography, and artificial intelligence methodsRheumatology International · 2025