The accuracy of pedicle screw placement in thoracolumbar fractures: A comparative study of automated cone-beam CT-based navigation and conventional fluoroscopy.
Kjell Alexander Thunes Akre, David Andreas Thomas Werner, Maziar Behbahani, Cecilia Isabella Alexandra Avellan, Knut Harboe, Eric Franssen, Anne Kristin Reve, Clemens Weber
Department of Neurosurgery, Stavanger University Hospital, Stavanger, Norway. · Department of Orthopaedic Surgery, Stavanger University Hospital, Stavanger, Norway.
Key points
From the paper's conclusion- Automated CBCT-based intraoperative 3D navigation provides high pedicle screw accuracy and comparable perioperative outcomes. CBCT-based navigation enables real-time 3D visualization and intraoperative verification, supporting its role as a reliable imaging modality in spine trauma surgery.
Abstract
INTRODUCTION: Pedicle screw fixation is a standard technique for stabilizing unstable thoracolumbar fractures. Mobile cone-beam CT (CBCT) systems with robotic image acquisition enable automated navigation workflows, but clinical data in spine trauma remain limited. RESEARCH QUESTION: To compare pedicle screw accuracy and perioperative outcomes between automated CBCT-based navigation and conventional fluoroscopy in thoracolumbar fracture fixation. MATERIAL AND METHODS: This single-centre retrospective cohort study included adults with unstable thoracolumbar spine injuries undergoing pedicle screw fixation during a 5.5-year period. In the CBCT group, intraoperative 3D navigation was performed using an automated CBCT system. Perioperative and postoperative variables were recorded, and screw placement was assessed using the Gertzbein-Robbins classification. Outcomes were compared between groups. RESULTS: Forty-six patients were included: 25 treated with automated CBCT-based navigation and 21 with conventional fluoroscopy. Among 313 evaluable screws, 96.8% were graded Gertzbein-Robbins A or B, and no grade E breaches were observed. In CBCT screws, no grade D or E breach occurred, and no screw-related early reoperations were required. Total operative time was longer with CBCT (154 vs. 119 min; p = 0.018), and blood loss was numerically higher (259 vs. 179 mL; p = 0.272), although operative time and blood loss per pedicle screw did not differ significantly between groups. Length of hospital stay and early clinical outcomes were comparable. CONCLUSION: Automated CBCT-based intraoperative 3D navigation provides high pedicle screw accuracy and comparable perioperative outcomes. CBCT-based navigation enables real-time 3D visualization and intraoperative verification, supporting its role as a reliable imaging modality in spine trauma surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficacy and Safety of Percutaneous Pedicle Screw Fixation for Neurologically Intact Thoracolumbar Burst Fractures: A Prospective Interventional Study.Cureus · 2026
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- Cone-Beam CT-Guided SpineJack® vertebral augmentation: A reproducible technique for accurate pedicular access and implant deployment.Injury · 2026
- Level-Specific Analysis of Intraoperative Computed Tomography-Navigated vs Fluoroscopy-Assisted Lumbar Pedicle Screw Placement Accuracy: A Retrospective Cohort Study.International journal of spine surgery · 2026
- Accuracy of 3D-navigated screw fixation in pelvic ring fractures: a single-centre consecutive observational case seriesEuropean Journal of Orthopaedic Surgery & Traumatology · 2025
- Accuracy of Pedicle Screw Placement at the Cervicothoracic Junction (C7–T2) : A Comparative Study of O-arm Navigation versus C-arm FluoroscopyJournal of Korean Neurosurgical Society · 2026