Efficacy and safety of artificial intelligence-assisted image-guided navigation in complex endovascular aortic repair: a systematic review and meta-analysis.
Judson C S Neri Júnior, Fernando C Batista, Raíssa V A Estevam, Bethânia C Heredia, Juliana A Tinoco, Gabriela V M M de Azevedo, Cristina R Riguetti-Pinto
Department of Medicine, Bahiana School of Medicine and Public Health, Salvador, Bahia, Brazil. Electronic address: judsonjunior23.2@bahiana.edu.br. · Faculty of Medicine, Centro Universitário FMABC (University Center of the ABC Region), Santo André, São Paulo, Brazil.
Key points
From the paper's conclusion- Cydar EV-assisted navigation may reduce radiation dose during complex endovascular aortic repair, but evidence is limited to retrospective studies of a single platform and does not establish a class effect for other AI-assisted navigation systems. Prospective comparative studies across platforms are needed.
Abstract
BACKGROUND: Complex endovascular aortic repair exposes patients and operators to substantial radiation, contrast, and long procedures. Artificial intelligence (AI)-assisted image-guided navigation, based on cloud-based three-dimensional image fusion, has been proposed to improve intraoperative guidance, but its comparative benefit is uncertain. METHODS: We searched MEDLINE, Embase, the Cochrane Library, and Web of Science (last search July 2025) for studies comparing AI-assisted image-guided navigation with conventional fluoroscopy and digital subtraction angiography during complex endovascular aortic repair. No navigation platform was prespecified. Random-effects meta-analyses yielded mean differences (MD) with 95% confidence intervals (CI); heterogeneity was quantified with I2. Risk of bias was assessed with ROBINS-I and certainty with GRADE. RESULTS: Three retrospective cohorts (332 patients; 189 AI, 143 control), all evaluating one cloud-based platform (Cydar EV), were eligible. AI-assisted navigation was associated with a lower radiation dose (2 studies, 216 patients; MD -1435.85 mGy, 95% CI -2208.84 to -662.86; I2 = 0%). No significant differences were found in fluoroscopy time (MD -11.04 minutes, 95% CI -25.37 to 3.29; I2 = 65%), operative time (MD -16.39 minutes, 95% CI -37.21 to 4.42; I2 = 0%), or contrast volume (MD -30.59 mL, 95% CI -73.95 to 12.76; I2 = 94%). Mortality and major adverse events (single studies) did not differ significantly. CONCLUSIONS: Cydar EV-assisted navigation may reduce radiation dose during complex endovascular aortic repair, but evidence is limited to retrospective studies of a single platform and does not establish a class effect for other AI-assisted navigation systems. Prospective comparative studies across platforms are needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Multi-Institution Analysis Demonstrates that Intelligent Maps Improve Intraoperative Safety and Efficiency During Fenestrated/Branched Endovascular Repairs.Annals of vascular surgery · 2026
- Artificial Intelligence for Computer-Aided Detection in Endovascular Interventions: Clinical Applications, Validation, and Translational PerspectivesBioengineering · 2026
- Artificial Intelligence in 3D Aortic CTA Segmentation for Abdominal Aortic Aneurysm Management: A Narrative Review.Journal of imaging · 2026
- Evaluation of clinical performance of artificial intelligence-assisted measurement of thoracic aortic diameter on non-contrast CT.Medicine · 2026
- Clinical evaluation of a novel artificial intelligence-based image processing algorithm for two-dimensional angiography.CVIR endovascular · 2026
- Prospective Shadow-Mode Evaluation of an Artificial Intelligence Tool for Intracranial Aneurysm Detection on CT Angiography: Incremental Yield and Operational Impact.Journal of the American College of Radiology : JACR · 2026