The Journal of arthroplasty

Worse Fixation of Cemented Patellar Components on Magnetic Resonance Imaging is Associated with Increased Patellar Component Surface Damage.

Richard Hwang, Sara E Sacher, Aarti A Shenoy, Hollis G Potter, Timothy M Wright, Douglas E Padgett

Department of Orthopedics, The Permanente Medical Group, Fremont, California. · Department of Biomechanics, Hospital for Special Surgery, New York, NY.

Key points

From the paper's conclusion
  • Cemented patellar components with MRI findings of an abnormal bone-cement interface and poor bone-cement integration demonstrated significantly higher surface damage scores. This relationship suggests that biomechanical factors such as wear and the accompanied increased contact loads are important factors in controlling component fixation.

Abstract

BACKGROUND: Cemented patellar components demonstrate high rates of fibrous tissue at the bone-cement interface on magnetic resonance imaging (MRI), suggesting worse fixation than femoral and tibial components. A paucity of data exists on modern patellar component wear patterns and the relationship with patellar fixation as assessed by MRI. We aimed to evaluate the in vivo wear patterns of patellar components and to determine if patellar components with worse fixation on MRI are associated with increased surface damage. METHODS: There were 122 cemented all-polyethylene patellar components (32 periprosthetic joint infection (PJI), 90 aseptic revision) revised between 2019 and 2024 that were analyzed. Surface damage was evaluated using the Hood scoring system (scale, 0 to 3). Preoperative multi-acquisition variable-resonance image combination (MAVRIC) MRI scans were reviewed following a validated method to evaluate the bone-cement interface and percentage of bone-cement integration for each patellar quadrant. RESULTS: Scratching, burnishing, and pitting were the most common modes of patellar component surface damage. The mean total Hood score was 10.4 (range, 1 to 24.5). The number of quadrants with an abnormal interface and the number of quadrants with ≤ 33% integration were associated with higher damage scores (P = 0.015 and P = 0.007, respectively). In multivariable analyses, men who had longer implantation duration and ≤ 33% integration in all quadrants on MRI were independently associated with higher articular surface damage scores. Increased patellar surface damage and poor bone-cement integration on MRI were associated with component loosening. CONCLUSION: Cemented patellar components with MRI findings of an abnormal bone-cement interface and poor bone-cement integration demonstrated significantly higher surface damage scores. This relationship suggests that biomechanical factors such as wear and the accompanied increased contact loads are important factors in controlling component fixation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers