The Journal of arthroplasty

Femoral Neck Morphology: A Computed-Tomography-Based Anatomic Framework Informs Medial Collar Design for Contemporary Collared Cementless Femoral Stems.

John J Kelly, Emma E Helgeson, Rakan R Alshaibi, Nicholas G Rhodes, Mark W Pagnano, Mario Hevesi

Division of Sports Medicine, Department of Orthopedics, Mayo Clinic, Rochester, MN, USA. · Department of Musculoskeletal Radiology, Mayo Clinic, Rochester MN, USA.

Key points

From the paper's conclusion
  • At and around the planned femoral neck osteotomy plane, medial and postero-medial cortices were thickest and increased in thickness distally, whereas antero-medial thickness plateaued. These data provide an anatomic reference that may inform cementless femoral stem collar geometry and future implant design.

Abstract

BACKGROUND: The level of femoral neck resection in total hip arthroplasty (THA) affects implant position, restoration of limb length, and degree of cortical support available for collared cementless stems. With increasing use of computed tomography (CT)-based planning and collared stems, understanding femoral neck and calcar morphology at the osteotomy plane is valuable. The aims of this study were to (1) quantify femoral neck cortical thickness at the achieved osteotomy plane reconstructed from postoperative imaging and adjacent levels, (2) assess the effect of osteotomy height on regional cortical support, and (3) determine the medial collar length that best matches cortical thickness at the osteotomy plane. METHODS: We reviewed preoperative CT scans from 100 consecutive primary THAs performed by a single surgeon using a single cementless femoral stem design. Using multiplanar reconstruction, calcar cortical thickness was measured on axial images at the osteotomy plane (zero mm) and at standardized levels 5.30 mm proximal and 5.30 mm distal to that plane. At each level, thickness was recorded at five locations (anterior, posterior, medial, antero-medial, and postero-medial). The medial cortical thickness at the osteotomy plane was used to determine the collar length, minimizing absolute overhang/underhang, which corresponds to its median. RESULTS: Cortical thickness increased from proximal to distal levels, most prominently in the medial (P < 0.001) and postero-medial (P < 0.001) regions. Antero-medial thickness increased from the proximal level to the osteotomy plane (P = 0.004), but did not increase further distally (P = 0.641). For this cohort and osteotomy technique, the collar length minimizing mean absolute overhang or underhang was 5.3 mm, the median medial cortical thickness at the osteotomy plane. CONCLUSION: At and around the planned femoral neck osteotomy plane, medial and postero-medial cortices were thickest and increased in thickness distally, whereas antero-medial thickness plateaued. These data provide an anatomic reference that may inform cementless femoral stem collar geometry and future implant design.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Femoral Neck Morphology: A Computed-Tomography-Based Anatomic Framework Informs Medial Collar Design for Contemporary Collared Cementless Femoral Stems — Science Skim