Fluoroscopy Computer Navigation Versus Manual Fluoroscopic Acetabular Positioning in Direct Anterior Total Hip Arthroplasty: Safe Zone Compliance and Learning Curve Analysis.
Karlos E Zepeda, Carmelo Burgio, Shrey Vachhani, Tsion Yared, Edward Grabov, Jonathan M Vigdorchik, Eytan M Debbi
Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Key points
From the paper's conclusion- Fluoroscopic based computer navigation was associated with higher safe zone compliance in DAA-THA with a rapid 6-case learning curve and reduced operative time, without increasing radiation exposure.
Abstract
BACKGROUND: Fluoroscopy is commonly leveraged in direct anterior approach total hip arthroplasty (DAA-THA). Computer-navigation systems provide real-time guidance aiming to enhance component positioning, but their learning curves and component accuracy remains incompletely characterized. This study evaluated the learning curve and safe zone compliance after implementation of computer navigation in DAA-THA. METHODS: This retrospective cohort study analyzed 200 consecutive primary DAA-THA cases performed by a single high-volume surgeon: 100 manual and 100 computer-navigated cases using the Velys Hip Navigation system. Acetabular component inclination and anteversion were measured on postoperative standing radiographs. Safe zone compliance was assessed using surgeon-defined, Lewinnek, and Callanan criteria. Learning curve analysis utilized segmented linear regression and cumulative sum methods. Operative time, fluoroscopy exposure, and component safe zone compliance were compared between groups. RESULTS: Operative time stabilized after 6 cases (P < .05), while significant breakpoint was identified for radiation exposure Computer navigated cases had shorter operative time (76.1 ± 16.4 vs 82.3 ± 17.0 minutes, P < .05) without increased fluoroscopy exposure (28.3 ± 6.6 vs 28.8 ± 9.8 seconds, P = .25). Safe zone compliance was significantly higher with navigation for surgeon-defined (98.9% vs 91.6%, P = .04), Lewinnek (86.3% vs 68.4%, P = .01), and Callanan criteria (68.4% vs 49.5%, P = .01). CONCLUSIONS: Fluoroscopic based computer navigation was associated with higher safe zone compliance in DAA-THA with a rapid 6-case learning curve and reduced operative time, without increasing radiation exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Evaluation of Precision in Implant Placement During the Early Learning Curve for the Direct Anterior Approach in Total Hip Arthroplasty.The Journal of the American Academy of Orthopaedic Surgeons · 2026
- Beyond robotics: a systematic review of technology integration in direct anterior approach total hip arthroplasty.Journal of robotic surgery · 2026
- Comparison of Fluoroscopy Use Between Two Radiographic Overlay Techniques for Limb Length and Femoral Offset Assessment During Direct Anterior Approach Total Hip Arthroplasty.Cureus · 2026
- Short-Term Clinicoradiological Outcomes of Primary Total Hip Arthroplasty With and Without Intraoperative Fluoroscopic Guidance: A Comparative Prospective Non-randomised Controlled (Quasi-experimental) Study.Journal of orthopaedic case reports · 2026
- Accurate Acetabular Component Positioning in Total Hip Arthroplasty Using Preoperative CT and Anatomical Landmarks.Journal of clinical medicine · 2026
- CT-based navigation for acetabular cup placement in supine and lateral positions: a simulated surgery study using patient-specific 3D-printed pelvic models.Frontiers in surgery · 2026