Comparison of Fluoroscopy Use Between Two Radiographic Overlay Techniques for Limb Length and Femoral Offset Assessment During Direct Anterior Approach Total Hip Arthroplasty.
Shivam H Patel, Alexander C Chong, Parth A Vyas
Orthopaedic Surgery, Sanford Health, Fargo, USA.
Key points
From the paper's conclusion- Both reference techniques had similar non-adjusted fluoroscopy time and exposure during DAA-THA; however, when normalized by operative time, the ipsilateral technique may require less fluoroscopy. BMI significantly influenced radiation dose and operative duration for both techniques. Ongoing critical evaluation of surgical techniques is essential to optimize safety, particularly when modifications may reduce radiation exposure to patients and operating room personnel.
Abstract
BACKGROUND: Restoration of leg length and femoral offset is critical to optimizing outcomes following total hip arthroplasty (THA). Several intraoperative techniques are available to assess these parameters when utilizing the direct anterior approach (DAA), many of which rely on fluoroscopy. However, relative radiation exposure associated with these strategies has not been well characterized. This study aims to compare intraoperative radiation exposure between two techniques for limb length and offset assessment during DAA-THA. METHODS: A retrospective chart review was conducted of 159 primary cementless DAA-THA procedures performed by a single fellowship-trained arthroplasty surgeon using either the contralateral or ipsilateral hip for length and offset reference. Medical records were reviewed to record fluoroscopy time, radiation dose, and operative time for each case. RESULTS: No statistical difference in fluoroscopy time was noted between contralateral (60.4 ± 21.2 seconds) and ipsilateral (55.9 ± 19.6 seconds) techniques (P = 0.17). Similarly, no statistical difference was noted for radiation exposure between contralateral (15.4 ± 13.3 mGy) and ipsilateral (13.0 ± 9.0 mGy) techniques (P = 0.17). However, when adjusted for operative time and presented as arbitrary units (AU), the ipsilateral technique was associated with less fluoroscopy time (0.34 ± 0.1 AU, P = 0.0025) and radiation exposure (0.08 ± 0.05 AU, P = 0.045) when compared to contralateral fluoroscopy time (0.39 ± 0.1 AU) and radiation exposure (0.1 ± 0.07 AU). Stratified analysis by body mass index (BMI) demonstrated a significant main effect of BMI on radiation exposure (P < 0.001) and operative time (P < 0.001). Regardless of technique, increasing BMI was positively correlated with higher radiation dose (r= 0.52, P < 0.001) and longer operative time (r = 0.42, P < 0.001). CONCLUSION: Both reference techniques had similar non-adjusted fluoroscopy time and exposure during DAA-THA; however, when normalized by operative time, the ipsilateral technique may require less fluoroscopy. BMI significantly influenced radiation dose and operative duration for both techniques. Ongoing critical evaluation of surgical techniques is essential to optimize safety, particularly when modifications may reduce radiation exposure to patients and operating room personnel.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Short-Term Clinicoradiological Outcomes of Primary Total Hip Arthroplasty With and Without Intraoperative Fluoroscopic Guidance: A Comparative Prospective Non-randomised Controlled (Quasi-experimental) Study.Journal of orthopaedic case reports · 2026
- Intraoperative six-axis loads during direct anterior approach total hip arthroplasty using a leg positioner: quantitative patterns across manoeuvres.International orthopaedics · 2026
- Fluoroscopy Computer Navigation Versus Manual Fluoroscopic Acetabular Positioning in Direct Anterior Total Hip Arthroplasty: Safe Zone Compliance and Learning Curve Analysis.Arthroplasty today · 2026
- Radiation stewardship in uniportal lumbar endoscopic decompression.Neurosurgical focus · 2026
- EP9.13 Sequential Releases for Femoral Mobilization During Direct Anterior Total Hip Arthroplasty: A Cadaveric Biomechanical ModelJournal of Hip Preservation Surgery · 2026
- An Evaluation of Precision in Implant Placement During the Early Learning Curve for the Direct Anterior Approach in Total Hip Arthroplasty.The Journal of the American Academy of Orthopaedic Surgeons · 2026