Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Novel data-processing method for determining the activity size distribution of unattached radon progeny with multi-layer perceptron machine learning algorithm.

Duanyang Ma, Jinmin Yang, Lei Zhang

State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing, 102205, China. · State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing, 102205, China. Electronic address: swofely@pku.edu.cn.

Computational

Key points

From the paper's conclusion
  • To achieve accurate measurement of the activity size distribution of unattached radon progeny, a new data-processing method based on the Multi-Layer Perceptron (MLP) machine learning algorithm and a Graded Screen Array (GSA) system was proposed, and a series of comparison experiments and field measurements were carried out.

Abstract

The activity size distribution of unattached radon progeny is a critical parameter for calculating radon exposure dose conversion coefficient. To achieve accurate measurement of the activity size distribution of unattached radon progeny, a new data-processing method based on the Multi-Layer Perceptron (MLP) machine learning algorithm and a Graded Screen Array (GSA) system was proposed, and a series of comparison experiments and field measurements were carried out. Comparison experiment results based on simulated data demonstrate that the solutions obtained by the MLP algorithms exhibit smaller deviation than that of the traditional Expectation Maximization (EM) algorithm and Twomey algorithm, and no ambiguous solutions is existed for different MLP algorithms and different activity size distribution. Comparison experiments based on field measurement data show that traditional inversion algorithms tend to produce ambiguous solutions and suffer from non-convergence in iteration, and thus exhibit lower reliability than the MLP algorithm. More field measurement results show that the activity size distribution of unattached radon progeny indoors and outdoors exhibit a unimodal distribution generally. The average Activity Median Diameter (AMD) is 2.63 nm and the average Geometric Standard Deviation (GSD) is 1.64 for indoors, while the average AMD is 2.84 nm and GSD is 1.49 for outdoors. The phenomenon that the AMD increasing with the relative humidity is observed in high humidity environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Novel data-processing method for determining the activity size distribution of unattached radon progeny with multi-layer perceptron machine learning algorithm — Science Skim