Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Can radon measurements in five ground-floor rooms enable a good decision on absence/presence of elevated radon levels in a multi-room building?

P Vukotić, M Benšić, V Radolić

Montenegrin Academy of Sciences and Arts, R. Stijovića 5, Podgorica, Montenegro. · School of Applied Mathematics and Informatics, University of Osijek, Trg Ljudevita Gaja 6, Osijek, Croatia.

Key points

From the paper's conclusion
  • For each building, five radon concentrations were randomly sampled from the measured values for all ground-floor rooms; this procedure was repeated 100 times.

Abstract

The aim of this study was to develop algorithms that, based on radon measurements in five ground-floor rooms of a large building all showing radon activity concentrations below 300 Bq m-3, could estimate, as accurately as possible, whether the remaining ground-floor rooms also have no radon concentrations above this reference level or whether such rooms are present. The algorithms were developed using radon activity concentration data from 105 public school and kindergarten buildings in Montenegro. In each building, passive detectors were exposed throughout the entire school year in ten or more ground-floor rooms. The building sample was diverse: 90 buildings were located in urban while 15 in rural areas; it included 12 kindergartens, 65 primary schools, and 28 secondary schools; the buildings varied considerably in age and construction characteristics. Seven algorithms were developed using two approaches. The first approach used the mean ratios of maximum-to-mean and maximum-to-median radon activity concentrations, calculated from data for all 105 buildings. The second approach assumed that ground-floor radon concentrations in each of the 105 buildings followed a lognormal distribution. The algorithms were validated using simulated data derived from the empirical distribution of radon activity concentrations in each individual building. For each building, five radon concentrations were randomly sampled from the measured values for all ground-floor rooms; this procedure was repeated 100 times. Of the seven algorithms, three performed better when no ground-floor room had a radon concentration at or above the reference level of 300 Bq m-3, yielding algorithms specificity of 90.5-96.9%. Three algorithms performed better when one or more ground-floor rooms had radon concentrations higher or equal than 300 Bq m-3, with algorithms sensitivity of 89.4-91.7%. One algorithm produced approximately equal sensitivity and specificity, of about 87%.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers