Patient-specific digital phantoms determined from effective atomic number and effective physical density images - Application of photon-counting computed tomography.
Rina Nishigami, Takashi Asahara, Natsumi Kimoto, Mana Mitani, Daiki Kobayashi, Takuya Kasue, Noriaki Akagi, Toshihiro Iguchi,
Graduate School of Medical Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan. Electronic address: nishigami.rina@gmail.com. · Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1, Shikata-cho, Kita-ku, Okayama, 700-8558, Japan. Electronic address: takashi.asahara.111@gmail.com.
Key points
From the paper's conclusion- When compared to conventional digital phantoms, the maximum differences were 1.67 for Zeff and 0.37 g/cm3 for ρeff.
Abstract
Virtual X-ray imaging experiments are a useful research approach that can provide insights into the development of novel technologies without radiation exposure. Recently, the development of advanced imaging techniques such as photon-counting detectors has been active, which increases the importance of basic research using virtual experiments. When the reproducibility of digital phantoms improves, more multifaceted virtual experiments can be conducted. The purpose of this study is to propose digital phantoms that accurately reproduce individual patients including their diseases. The phantom voxel data were described by the effective atomic number (Zeff) and effective physical density (ρeff) values. These values were derived from quantitative analysis of virtual monoenergetic images (VMIs) obtained with clinical photon-counting CT. Then, 10 patient datasets were analyzed, and the components of normal tissues and disease tissues were investigated. The Zeff and ρeff of typical organs were in good agreement with the well-known database. The differences for soft tissue organs (liver, kidneys, spleen, skeletal muscles, and aorta) were 0.1-2.1%, and those for bone organs (bone marrow and cortical bone) were 1.6-30%. In contrast, in disease tissues, different combinations of Zeff and ρeff were observed depending on the disease type. When compared to conventional digital phantoms, the maximum differences were 1.67 for Zeff and 0.37 g/cm3 for ρeff. Consequently, our digital phantom accurately reproduced not only normal tissues but also disease tissues without using reference data. The proposed phantom will contribute to enhancing the potential of virtual imaging experiments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An algorithm to calculate physical density of biomedical objects having 3 ≤ Zeff ≤ 20: an application study using clinical photon-counting computed tomography equipmentApplied Radiation and Isotopes · 2026
- Validation of a novel 3D-printed anthropomorphic pediatric abdomen phantom using photon-counting CTScientific Reports · 2025
- Impact of acquisition parameters in photon-counting computed tomography on the stability of virtual monoenergetic attenuation values and effective atomic number: a phantom study.European journal of radiology · 2026
- Photon-Counting CT With Low-keV Virtual Monoenergetic Images for Detecting Muscle Invasion in Bladder Cancer: A Prospective Study.AJR. American journal of roentgenology · 2026
- Practical applications of photon-counting CT in oncology: an organ-based pictorial review.Insights into imaging · 2026
- Quantitative comparison of virtual non-contrast and true non-contrast computed tomography pulmonary angiography images across eight thoracic tissue types: A retrospective cross-sectional study.The Journal of international medical research · 2026