Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Patient-specific digital phantoms determined from effective atomic number and effective physical density images - Application of photon-counting computed tomography.

Rina Nishigami, Takashi Asahara, Natsumi Kimoto, Mana Mitani, Daiki Kobayashi, Takuya Kasue, Noriaki Akagi, Toshihiro Iguchi,

Graduate School of Medical Sciences, Kanazawa University, 5-11-80, Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan. Electronic address: nishigami.rina@gmail.com. · Department of Radiological Technology, Faculty of Health Sciences, Okayama University, 2-5-1, Shikata-cho, Kita-ku, Okayama, 700-8558, Japan. Electronic address: takashi.asahara.111@gmail.com.

Key points

From the paper's conclusion
  • When compared to conventional digital phantoms, the maximum differences were 1.67 for Zeff and 0.37 g/cm3 for ρeff.

Abstract

Virtual X-ray imaging experiments are a useful research approach that can provide insights into the development of novel technologies without radiation exposure. Recently, the development of advanced imaging techniques such as photon-counting detectors has been active, which increases the importance of basic research using virtual experiments. When the reproducibility of digital phantoms improves, more multifaceted virtual experiments can be conducted. The purpose of this study is to propose digital phantoms that accurately reproduce individual patients including their diseases. The phantom voxel data were described by the effective atomic number (Zeff) and effective physical density (ρeff) values. These values were derived from quantitative analysis of virtual monoenergetic images (VMIs) obtained with clinical photon-counting CT. Then, 10 patient datasets were analyzed, and the components of normal tissues and disease tissues were investigated. The Zeff and ρeff of typical organs were in good agreement with the well-known database. The differences for soft tissue organs (liver, kidneys, spleen, skeletal muscles, and aorta) were 0.1-2.1%, and those for bone organs (bone marrow and cortical bone) were 1.6-30%. In contrast, in disease tissues, different combinations of Zeff and ρeff were observed depending on the disease type. When compared to conventional digital phantoms, the maximum differences were 1.67 for Zeff and 0.37 g/cm3 for ρeff. Consequently, our digital phantom accurately reproduced not only normal tissues but also disease tissues without using reference data. The proposed phantom will contribute to enhancing the potential of virtual imaging experiments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.