Dosimetric comparison of wedge, field-in-field, IMRT, VMAT and hybrid radiotherapy techniques: A systematic review.
Evi Afrianti, Dahlang Tahir, Sri Dewi Astuty
Department of Physics, Hasanuddin University, Tamalanrea, Makassar, 90245, Indonesia. · Department of Physics, Hasanuddin University, Tamalanrea, Makassar, 90245, Indonesia. Electronic address: dtahir@fmipa.unhas.ac.id.
Key points
From the paper's conclusion- Hybrid radiotherapy represents the optimal compromise between dosimetric quality, OAR protection, and treatment efficiency. FIF is superior to wedge for simple geometries, VMAT is preferred for complex targets, and hybrid techniques are recommended when both conformity and OAR sparing are critical.
Abstract
BACKGROUND: Radiotherapy is a key modality in cancer treatment, requiring a balance between sufficient dose delivery to the Planning Target Volume (PTV) and minimizing radiation exposure to surrounding organs at risk (OAR). The evolution of techniques from wedge-based conventional planning to Field-in-Field (FIF), Intensity-Modulated Radiotherapy (IMRT), Volumetric Modulated Arc Therapy (VMAT), and most recently, hybrid planning aims to improve dose homogeneity, conformity, and treatment efficiency. OBJECTIVE: To systematically compare dosimetric performance among wedge, FIF, IMRT, VMAT, and hybrid techniques in terms of dose homogeneity (HI), conformity (CI), PTV coverage, OAR sparing, and monitor unit (MU) efficiency. METHODS: A systematic literature review was conducted following PRISMA 2020 guidelines. Articles were retrieved from PubMed, Scopus, ScienceDirect, and Google Scholar (2015-2025). Studies were included if they reported comparison of ≥2 techniques and provided dosimetric parameters (HI, CI, PTV coverage, OAR dose, and/or MU). There are 25 eligible studies covering breast, prostate, head and neck, rectal, lung, and whole-brain radiotherapy were analyzed. RESULTS: FIF consistently demonstrated better dose homogeneity and reduced hotspots than wedge techniques. IMRT and VMAT improved conformity and PTV coverage, with VMAT offering higher delivery efficiency due to lower MU requirements. Hybrid techniques combining FiF/3DCRT with IMRT or VMAT provided the most balanced outcomes: improved HI and CI, reduced low-dose spread, and lower OAR exposure, particularly to heart and ipsilateral lung in left-sided breast irradiation. CONCLUSION: Hybrid radiotherapy represents the optimal compromise between dosimetric quality, OAR protection, and treatment efficiency. FIF is superior to wedge for simple geometries, VMAT is preferred for complex targets, and hybrid techniques are recommended when both conformity and OAR sparing are critical.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dosimetric Comparison of Five Radiotherapy Techniques in Left-Sided Breast Cancer Patients Following Breast-Conserving Surgery.The breast journal · 2026
- Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026
- Evaluation of 3D-CRT vs. VMAT for radiotherapy of whole breast with simultaneous integrated boostActa Oncologica · 2026
- Toward optimal radiotherapy in tongue cancer: a comparative study of IMRT and VMAT.Radiological physics and technology · 2026
- A Unified Planning Platform Comparison of VMAT, Helical Tomotherapy, and IMRT in Nasopharyngeal Carcinoma: Dosimetric Superiority and Organ Sparing AnalysisTechnology in Cancer Research & Treatment · 2026
- RapidArc dynamic versus IMRT and VMAT for endometrial cancer SIB radiotherapy.Radiation oncology (London, England) · 2026