Optimizing dosimeter placement for radiation protection in nuclear medicine: A Monte Carlo simulation study.
Fatemeh Aryan, Hossein Rajabi, Pouya Saraei, Arsalan Hasnaki, Saman Dalvand
Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran. · Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran; Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Key points
From the paper's conclusion- The simulations indicate that dosimeter position can influence the interpretation of exposure in partially shielded nuclear medicine workers. The findings support further experimental and occupational-dosimetry evaluation of task- and geometry-specific monitoring configurations, rather than immediate modification of occupational monitoring protocols or radiation-protection guidelines.
Abstract
PURPOSE: This study examined the optimal placement of personal dosimeters for radiation workers in nuclear medicine to improve the accuracy of organ dose estimation, particularly in the presence of lead apron shielding. METHODS: Monte Carlo simulations were carried out using the GATE toolkit with the Livermore low-energy physics model. ICRP reference male and female computational phantoms were used as radiation-worker models, and an additional ICRP male phantom represented the patient/source. F-18, I-131, and Tc-99m were simulated at source-to-worker distances of 0, 1, and 3 m with lead-equivalent apron thicknesses of 0, 0.125, 0.25, and 0.5 mm. The radionuclide source was represented by a uniform cylindrical tissue-equivalent volume. Simulations used 10^8 primary-particle histories per modeled condition; no patient-specific administered activity was assigned. RESULTS: The outer and under-apron dosimeters showed different relationships with doses to uncovered and apron-covered organs, respectively. Linear fits for F-18 had R2 > 0.90, whereas logarithmic fits for I-131 and Tc-99m had R2 > 0.85. Increasing apron thickness changed under-apron readings in a radionuclide-, phantom-, and geometry-dependent manner, with the largest relative changes observed for Tc-99m. Source-to-worker distance generally reduced the modeled dose readings. These findings describe the behavior of the modeled exposure geometry but do not constitute clinical validation of a dual-dosimeter protocol. CONCLUSION: The simulations indicate that dosimeter position can influence the interpretation of exposure in partially shielded nuclear medicine workers. The findings support further experimental and occupational-dosimetry evaluation of task- and geometry-specific monitoring configurations, rather than immediate modification of occupational monitoring protocols or radiation-protection guidelines.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- PHITS Monte Carlo zoning and workplace studies of medical radiographic rooms.Physical and engineering sciences in medicine · 2026
- Occupational exposure assessment in ROLL procedures with Tc-99m: A Monte Carlo simulation approach.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Influence of forehead gap size on eye protection provided by lead eyewear worn over prescription glasses: A Monte Carlo studyMedical Physics · 2026
- Integrated spatiotemporal assessment of ambient radiation fields in a nuclear medicine department using OSL and time-resolved Geiger-Müller monitoring.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Comparing monitored occupational exposure and unmonitored indoor radon in healthcare settings.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Low-dose ionizing radiation exposure and tumor risk: An umbrella review of systematic reviews and meta-analyses.Journal of hazardous materials · 2026