Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Comparing monitored occupational exposure and unmonitored indoor radon in healthcare settings.

Ylli Kaçiu, Margarita Kuqali Hima, Blerim Rrakaqi, Njomza Elezaj, Gazmend Nafezi, Ismet Bajrami

Faculty for Mathematics and Physics Engineering - Polytechnic University of Tirana, Tirana, Albania. · Alma Mater Europaea College REZONANCA, Prishtina, Republic of Kosovo. Electronic address: blerim.rrakaqi@rezonanca-rks.com.

Key points

From the paper's conclusion
  • Indoor radon represents an environmental radiation component that may remain outside routine occupational monitoring in healthcare settings. Integrating indoor radon assessment with established occupational radiation-protection programs may provide a more comprehensive characterization of radiation exposure in healthcare environments.

Abstract

BACKGROUND AND AIM: Occupational exposure to artificial ionizing radiation in healthcare is routinely monitored through personal dosimetry, whereas indoor radon may remain outside routine institutional radiation-protection monitoring. This study aimed to compare routinely monitored occupational exposure with estimated effective doses associated with measured indoor radon concentrations within the same healthcare setting, and to assess the relative contribution of these two radiation-exposure pathways. METHODS: Thermoluminescent dosimeter (TLD) data were evaluated over a six-year period for 20-27 professionally exposed nuclear medicine workers per year, followed by an additional 12-month period of optically stimulated luminescence (OSL) monitoring. Indoor radon concentrations were independently measured using passive CR-39 solid-state nuclear track detectors deployed in 31 selected healthcare locations for approximately 94 days. Radon-related annual effective doses were estimated using standard dose-conversion assumptions. RESULTS AND DISCUSSION: Mean annual occupational doses during the TLD monitoring period ranged from 1.22 to 1.44 mSv, while the subsequent OSL monitoring period yielded higher recorded values. Indoor radon concentrations ranged from 24 to 360 Bq m-3, with a mean of 71.97 Bq m-3, corresponding to a mean estimated annual effective dose of 0.52 mSv y-1 under occupational occupancy assumptions. The radon-related dose therefore represented a measurable environmental radiation component that was not captured by routine personal dosimetry. Although occupational personal dose equivalent, Hp(10), and radon-derived effective dose are not strictly equivalent dosimetric quantities, consideration of their relative magnitudes highlights a potential asymmetry between routinely monitored artificial-source exposure and an independently assessed natural-radiation component. CONCLUSION: Indoor radon represents an environmental radiation component that may remain outside routine occupational monitoring in healthcare settings. Integrating indoor radon assessment with established occupational radiation-protection programs may provide a more comprehensive characterization of radiation exposure in healthcare environments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers