The influence of hypoxia and hypercapnia on Gafchromic™ MD-V3 and HD-V2 film response during 60Co gamma irradiation.
Hanano Yamada, Andrew G Parker
Insect Pest Control Section, Joint FAO/IAEA Centre of Nuclear Techniques in Food and Agriculture, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria. Electronic address: h.yamada@iaea.org. · Insect Pest Control Section, Joint FAO/IAEA Centre of Nuclear Techniques in Food and Agriculture, Department of Nuclear Sciences and Applications, International Atomic Energy Agency, Vienna, Austria. Electronic address: a.g.parker@protonmail.com.
Key points
From the paper's conclusion- This study investigated the influence of hypoxia and hypercapnia on the dose response of Gafchromic™ MD-V3 (35 Gy) and HD-V2 (350 Gy) films during 60Co gamma irradiation.
Abstract
The response of radiochromic film dosimeters may be influenced by environmental conditions during irradiation, yet the effect of atmospheric composition has not been quantified for current Gafchromic™ formulations. This study investigated the influence of hypoxia and hypercapnia on the dose response of Gafchromic™ MD-V3 (35 Gy) and HD-V2 (350 Gy) films during 60Co gamma irradiation. Films were exposed to controlled atmospheres (≤0.2-21% O2 and CO2/O2/N2 mixtures) prior to and during irradiation, and optical density was measured at 590 nm 24 h post-irradiation. MD-V3 film exhibited a significant dependence on oxygen concentration and pre-irradiation hypoxic exposure time. Response increased with duration of hypoxic exposure and declined linearly with log oxygen concentration between 0.5% and 21% O2. Post-irradiation atmosphere also influenced the final response of films previously exposed to hypoxia, with a greater response observed when hypoxia-conditioned films were returned to air after irradiation than when they remained under hypoxia. Hypercapnic mixtures produced changes consistent with oxygen displacement, indicating that response variation was governed primarily by oxygen concentration rather than CO2. In contrast, HD-V2 film showed no significant dependence on atmospheric composition under the conditions tested. These results demonstrate that atmospheric composition represents a relevant influence quantity for MD-V3 dosimetry. Calibration performed under normoxic conditions may introduce systematic bias when films are used in modified-atmosphere irradiation processes. Atmospheric conditions before, during and, under some circumstances, after irradiation should therefore be considered when MD-V3 film is used for dosimetry under modified atmospheres.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A review on radiochromic film dosimetry in radiation therapyJournal of Applied Clinical Medical Physics · 2025
- Radiation-Sensitive Thin Film Dosimeter Based on Polyvinyl Alcohol (PVA)/Hafnium Dioxide (HfO2)/Silver Nitrate (AgNO3) Composite: Colorimetric Characterization and Dose-Response Analysis for Low-Dose Gamma-Ray Applications.Polymers · 2026
- Humidity effects in GafChromicTMEBT4 films for postal audits: characterization, reversibility and exploration of correction methods.Physics in medicine and biology · 2026
- Comparative analysis of the responses of EBT-XD and EBT4 films to ultra-high dose rate proton beamsRadiation Physics and Chemistry · 2025
- Response of the peeled off Gafchromic EBT2 film to 4 MeV alpha particles using transmission and reflection modes.Scientific reports · 2026
- Effect of scanning position and orientation on the readout of Gafchromic film scanned with two different light-emitting flatbed scanners.Radiation and environmental biophysics · 2026