From the paper's conclusion- These results demonstrate that geometric representation influences dose estimates even in homogeneous phantoms.
Abstract
This study compares two geometric modeling approaches for the computational representation of the three-dimensional Angelika phantom, which is a quality-assurance phantom developed for gynecological brachytherapy applications. A Surface Mesh model and a Macrobodies model were implemented in MCNP6.2 to calculate absorbed dose distributions in Gafchromic EBT3 films irradiated by a192Ir HDR source positioned at different locations along the phantom axis. Both approaches reproduced similar angular and longitudinal dose distribution patterns. Higher absorbed dose rates were observed at 45° and 225°, while lower values were found in the phantom plug region due to increased PMMA attenuation. The Surface Mesh model systematically yielded higher absorbed dose rates than the Macrobodies model, with an average difference of approximately 4% and a maximum local difference of 27%. Relative errors associated with the Monte Carlo simulations remained below 1.6% in all scenarios. These results demonstrate that geometric representation influences dose estimates even in homogeneous phantoms. Both approaches proved suitable for quality-assurance applications. However, the Surface Mesh model provided greater geometric fidelity and a closer representation of the original phantom geometry, making it a valuable tool for Monte Carlo benchmarking studies in brachytherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical test cases for commissioning, QA, and benchmarking of model‐based dose calculation algorithms in¹ ⁹² Ir HDR gynecologic tandem and ring brachytherapyMedical Physics · 2026
- Experimental and Monte Carlo TG-43 characterization of the HDR 192 Ir Flexisource: A combined EBT3 film and GATE studyEPJ Web of Conferences · 2026
- Monte Carlo intercomparison of TG-43 dosimetric parameters for clinical192Ir and125I brachytherapy sources.Physics in medicine and biology · 2026
- Evaluation of Dose to Medium and Dose to Water with the Acuros XB Algorithm for SABR: Clinical and Phantom-Based Observations.Biomedical physics & engineering express · 2026
- Dosimetric comparison of HDR Co-60 and Ir-192 brachytherapy sources by model-based dose calculation algorithms and its clinical implication in different brachytherapy sites and techniques.Brachytherapy · 2026
- Investigation of TG-43 dose calculation algorithm for volumetric HDR Brachytherapy using Monte Carlo simulation in TOPAS.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026