Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications.
Jielong Lin, Jiawei Long, Xinye Xia, Zhenyi Li, Wenliang Guo, Xiaofeng Wu, Cheng Hong
Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510010, China (J.L.). · State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, National Center for Respiratory Medicine, Joint International Research Laboratory of Respiratory Health, Guangdong Basic Research Center of Excellence for Respiratory Medicine, Department of Respiratory, Guangzhou Institute of Respiratory Health, the First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong 510163, PR China (J.L., X.X., W.G., X.W., C.H.); Guangzhou National Laboratory, No. 9 XingDaoHuanBei Road, Guangzhou International Bio Island, Guangzhou, Guangdong Province, 510005, China (J.L.).
Key points
From the paper's conclusion- Intraoperative CBCT provides reliable assessment of stent geometry during PPVSA. In addition to demonstrating strong agreement with first follow-up CTPA, CBCT-derived morphologic parameters may be associated with procedural hemodynamic improvement and may provide supplemental information regarding subsequent stent patency and long-term outcomes.
Abstract
RATIONALE AND OBJECTIVES: Percutaneous Pulmonary Vascular Stent Angioplasty (PPVSA) is a key treatment for pulmonary vascular stenosis in Fibrosing Mediastinitis (FM). This study evaluated the added value of intraoperative cone-beam computed tomography (CBCT) beyond conventional angiography for post-stenting assessment during PPVSA. MATERIALS AND METHODS: This retrospective single-center study included 54 consecutive FM patients who underwent PPVSA between August 2021 and May 2024, comprising 114 stents (99 arterial and 15 venous). All patients underwent intraoperative CBCT, angiography, and follow-up computed tomography pulmonary angiography (CTPA) for assessment of stent geometry. Agreement between imaging modalities was evaluated using correlation, Bland-Altman, and reproducibility analyses. Associations between CBCT-derived parameters, hemodynamic outcomes, and stent patency were further explored. RESULTS: Among 54 patients (57.26 ± 11.47 years; 17 females [31.48%]), CBCT demonstrated excellent correlation with first follow-up CTPA. For maximum stent diameter, the correlation between CBCT and CTPA was r = 0.99, compared with r = 0.94 for angiography. For minimum stent diameter, the corresponding correlations were r = 0.99 and r = 0.85, respectively (all p < 0.001). Bland-Altman analysis showed smaller measurement bias and narrower limits of agreement for CBCT than for angiography. During a median imaging follow-up of 614.50 days, in-stent restenosis occurred in 15.79% of stents, whereas complete stent occlusion occurred in 1.75% of stents. Stents with a minimum-to-maximum diameter ratio <80% showed higher restenosis rates than those with a ratio ≥80% (24.00% vs. 9.38%, p = 0.017). In addition, among pulmonary arterial stents, a CBCT-derived stent relief index was positively correlated with trans-lesional systolic pressure gradient reduction (r = 0.249, p = 0.033). CONCLUSION: Intraoperative CBCT provides reliable assessment of stent geometry during PPVSA. In addition to demonstrating strong agreement with first follow-up CTPA, CBCT-derived morphologic parameters may be associated with procedural hemodynamic improvement and may provide supplemental information regarding subsequent stent patency and long-term outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prediction of treatable occluded branches before balloon pulmonary angioplasty using CT imaging in patients with chronic thromboembolic pulmonary hypertensionEuropean Heart Journal · 2026
- Ultra-high-resolution Photon-Counting CT for Leaflet-Specific Evaluation of Fibrosis and Calcification in Aortic StenosismedRxiv · 2026
- Quantitative static contrast-enhanced phantom study to establish performance of advanced cone beam computed tomography for functional imaging applications.Physics and imaging in radiation oncology · 2026
- FP7.7 Cone Beam Tomosynthesis Fluoroscopy (CBTF) imaging utilization in periacetabular osteotomy (PAO) surgeryJournal of Hip Preservation Surgery · 2026
- Looking to the Future: The Emerging Role of Fractal Analysis in Cardiac CT.Journal of imaging · 2026
- Agreement of noninvasive multimodality imaging measurements with balloon sizing in the cardiac catheterization laboratory prior to percutaneous pulmonary valve implantation.The Journal of invasive cardiology · 2026