FP7.7 Cone Beam Tomosynthesis Fluoroscopy (CBTF) imaging utilization in periacetabular osteotomy (PAO) surgery

Dr Jeffrey Peck, Dr Benjamin Martin, Dr Syed Ahmed, Dr Matthew Oetgen, Rati Deshpande, Kevin Cleary

Observational · n=18

Key points

From the paper's conclusion
  • This study evaluated the reliability of 2D assessment with CBTF in comparison to x-rays and standard fluoroscopy imaging in PAO surgery.

Abstract

ICLB07 - The Digital Surgeon: Practical Tools and Navigation Basics for Your Everyday Practice, Session Room 12 (BMCC Level 3), October 8, 2026, 14:00 - 16:00 Introduction The periacetabular osteotomy (PAO) is a complex surgery used to treat symptomatic acetabular dysplasia. Surgical success depends upon accurate intra-operative acetabular fragment positioning. Enhanced outcomes may be achieved with imaging modalities that provide intra-operative 3-dimensional (3D) visualization, such as Cone Beam Tomosynthesis Fluoroscopy (CBTF). CBTF provides fast intra-operative 3D and 2D imaging. This study evaluated the reliability of 2D assessment with CBTF in comparison to x-rays and standard fluoroscopy imaging in PAO surgery. Methods A prospective, IRB-approved, single institution study was conducted evaluating PAO patients. Lateral Center Edge Angle (LCEA), Tönnis angle, Anterior Center Edge Angle (ACEA) were measured on x-ray, fluoroscopy, and CBTF before and after PAO correction. Power analysis demonstrated n=18 as the minimum study participants needed. Agreement across imaging modalities was assessed using Intraclass Correlation Coefficients (ICC). Differences between modalities were evaluated using a Friedman test. Bland-Altman analysis assessed agreement and quantified bias between imaging techniques by evaluating mean differences and limits of agreement, indicating how closely radiographic measurements correspond for each patient. Results Twenty-two patients were included. Preoperative agreement across x-ray, fluoroscopy, and CBTF imaging was excellent for LCEA (ICC = 0.956) and Tönnis angle (ICC = 0.904), and good for ACEA (ICC = 0.778). Postoperatively, LCEA maintained good agreement (ICC = 0.768), Tönnis angle had moderate agreement (ICC = 0.587), and ACEA demonstrated poor-to-moderate agreement (ICC = 0.404). No significant differences (Friedman test) were observed across modalities for LCEA at either timepoint (p > 0.05), whereas significant differences were identified for Tönnis angle and ACEA. These findings indicate that LCEA is the most reliable measurement across imaging modalities, while ACEA demonstrates variability. Bland-Altman analysis showed minimal bias and narrow limits of agreement for LCEA, while ACEA demonstrated more variability. Pairwise analysis demonstrated x-ray measurements aligned most closely with CBTF for LCEA, with tighter agreement than when compared to fluoroscopy. Conclusion Pre-operative and post-operative CBTF LCEA measurements had strong agreement with better correlation to x-ray than fluoroscopy. These findings indicate that CBTF provides valuable intra-operative imaging assessment. Further investigations utilizing CBTF 3D abilities to guide and navigate PAO osteotomies, correction, and implant placement are warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

FP7.7 Cone Beam Tomosynthesis Fluoroscopy (CBTF) imaging utilization in periacetabular osteotomy (PAO) surgery — Science Skim