Diagnostic Utility of Accommodative Measurements by Nott Dynamic Retinoscopy in Children with Unilateral Amblyopia.
Aparna Raghuram, Tawna L Roberts, Yufeng Zhu, Heather A Anderson, Ruth E Manny, Vivian M Manh, Sophia M Marusic, Surbhi Bansal,
Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA. · Spencer Center for Vision Research, Byers Eye Institute at Stanford University, Palo Alto, California, USA.
Key points
From the paper's conclusion- NDR is not interchangeable with instrument-based objective accommodative measures in children with and without amblyopia; however, it may be useful as a screening tool for abnormal accommodative amplitude and accuracy, pending confirmation in larger, independent cohorts.
Abstract
PURPOSE: To evaluate the agreement and diagnostic utility of Nott Dynamic Retinoscopy (NDR) compared with instrument-based methods for assessing accommodative amplitude, accuracy and variability in children with unilateral amblyopia. METHODS: Children aged 5-10 years with unilateral amblyopia (6/12-6/30, N = 42) and without amblyopia (6/7.5 or better, N = 51) were enrolled. Accommodative parameters were assessed using NDR and instrument-based methods: Grand Seiko autorefractor for amplitude and accuracy and PowerRef 3 for variability. Participants monocularly viewed 6/45 letters on an iPod at 33 cm for accuracy and variability; the same letters were viewed at progressively closer test distances and through minus lenses for amplitude assessment. Agreement between NDR and instrument-based measures was evaluated using Bland-Altman analysis. Instrument-based values from controls established abnormal thresholds, defined as worse than the 1-sided 95% tolerance limits with 90% confidence. NDR cut-offs for detecting abnormal accommodation values were derived using receiver operating characteristic (ROC) curves. RESULTS: Agreement between NDR and instrument-based methods was poor for all accommodative parameters with wide limits of agreement. Based on instrument-based tolerance limits, 39% of amblyopic eyes had abnormal amplitude (≤6.63 D), 34% had abnormal accuracy (lag ≥2.12 D) and 7% had abnormal variability (≥0.98 D). For amplitude, an NDR cut-off ≤5.60 D provided 80% sensitivity (95% CI, 60-100%) and 80% specificity (95% CI, 64-96%) to detect abnormality (area under the ROC curve [AUROC] = 0.85). For accuracy, an NDR cut-off ≥1.55 D provided 92% sensitivity (95% CI, 76-100%) and 81% specificity (95% CI, 67-96%) (AUROC = 0.90). There were insufficient participants with abnormal accommodative variability using the PowerRef 3 to establish an NDR threshold. CONCLUSIONS: NDR is not interchangeable with instrument-based objective accommodative measures in children with and without amblyopia; however, it may be useful as a screening tool for abnormal accommodative amplitude and accuracy, pending confirmation in larger, independent cohorts.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nil Stereoacuity in Amblyopia and Strabismus: A Methodological Systematic Review.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
- Analysis of the application of computerized optokinetic nystagmus analyzer in vision examination.BMC ophthalmology · 2026
- Beyond static assessment: dynamic accommodative behaviour across refractive states.Clinical & experimental optometry · 2026
- Variability in Refractive Measurements in Children with Autism Spectrum Disorder Under Cycloplegic and Non-Cycloplegic Conditions: Influence of Measurement Method.Journal of clinical medicine · 2026
- Automated pupillometric quantification of relative afferent pupillary defect: comparison with neutral density filter grading in unilateral/asymmetric optic neuropathy.Documenta ophthalmologica. Advances in ophthalmology · 2026
- Photoreceptor mosaic characteristics in Patients with Refractory Amblyopia Using Adaptive Optics Scanning Laser Ophthalmoscopy.Photodiagnosis and photodynamic therapy · 2026