A multi-task Bayesian Hierarchical Gated Transformer for predicting postoperative vault after Implantable Collamer Lens implantation
Yang Li, Jiaojiao Wang, Jue Wang
Key points
From the paper's conclusion- MBHGT combined a Transformer backbone with a Bayesian approximation to quantify predictive uncertainty, a hierarchical gated module for dynamic feature interaction, and a multi-task framework for joint regression and risk stratification.
Abstract
Accurate prediction of postoperative vault following Implantable Collamer Lens (ICL) implantation is important for surgical safety, as an inappropriate vault may contribute to complications such as angle closure, cataract formation, and elevated intraocular pressure. Despite advancements in preoperative biometric measurements, existing Machine Learning (ML) approaches often have difficulty accounting for the multifactorial dependencies and inherent uncertainties in clinical data. To address these issues, this study proposed a Multi-task Bayesian Hierarchical Gated Transformer (MBHGT). The model was developed and evaluated on a retrospective dataset of 324 eyes (162 patients) using 16 preoperative parameters. MBHGT combined a Transformer backbone with a Bayesian approximation to quantify predictive uncertainty, a hierarchical gated module for dynamic feature interaction, and a multi-task framework for joint regression and risk stratification. In comparative experiments, MBHGT achieved a Mean Absolute Error (MAE) of 138.01 μm in continuous vault prediction, outperforming the compared baselines. In a 3-class vault classification task (low, normal, high), MBHGT attained a macro-AUC of 0.86 and a macro-F1 score of 0.68, mitigating the majority-class bias commonly observed in conventional models. Quantitative uncertainty evaluation suggested reasonable predictive calibration in both the regression and classification tasks. SHAP-based interpretability analysis quantified individual feature contributions and identified Horizontal Sulcus-to-Sulcus distance (STS), ICL size, and Lens Thickness (LT) as the dominant predictors in our dataset. By combining predictive performance with interpretability, MBHGT shows promise as a decision-support tool for postoperative vault prediction; however, multi-center external and prospective validation is required before clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Machine-learning prediction of high implantable collamer lens vault using angle-to-angle anatomy: a patient-grouped internal validation study.Frontiers in cell and developmental biology · 2026
- Research on a New Model for Predicting Vault After Implantable Collamer Lens (ICL) Based on Structural Parameters of the Posterior Chamber.Journal of ophthalmology · 2026
- Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- ICL Sizing and Vault Prediction: A Systematic Review of Mathematical Models and Calculation Formulas.Seminars in ophthalmology · 2026
- Accuracy of NK and KS Formulas in Predicting Postoperative Vault at One Month After Implantable Collamer Lens Implantation: A Retrospective Study of 327 Eyes.Clinical ophthalmology (Auckland, N.Z.) · 2026