Machine-learning prediction of high implantable collamer lens vault using angle-to-angle anatomy: a patient-grouped internal validation study.
Hui Li, Runzhang He, Sheng Zhou, Jing Yang
Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China. · State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China.
Key points
From the paper's conclusion- Conclusion ATA-based models improved prediction of both high and continuous 1-week ICL vault compared with otherwise matched WTW-based models.
Abstract
BACKGROUND: Machine learning has increasingly been applied to implantable collamer lens (ICL) vault prediction, but the value of anatomically informed feature representation remains uncertain. We evaluated whether angle-to-angle (ATA)-centered anatomy improves prediction of high and continuous postoperative vault compared with white-to-white (WTW)-centered anatomy. METHODS: This retrospective study included 279 eyes from 152 patients with 1-week postoperative vault measurements. Matched regularized supervised machine-learning models were constructed using either ICL size minus WTW or ICL size minus ATA; an expanded ATA model additionally included crystalline lens rise and nasal and temporal anterior chamber angles. Models were internally validated using patient-grouped nested cross-validation, with fellow eyes kept together throughout validation. High vault (>750 µm) was the primary binary outcome, continuous vault was evaluated as a secondary outcome, and low vault (<250 µm) was exploratory. Confidence intervals and between-model differences were estimated using patient-cluster bootstrap sampling. RESULTS: High vault occurred in 77 eyes (27.6%) from 49 patients. The ATA-centered model achieved a higher AUC for high-vault prediction than the WTW-centered model (0.805 [95% CI, 0.738-0.864] vs. 0.743 [95% CI, 0.667-0.814]), with a paired difference of 0.063 (95% CI, 0.011-0.118). For continuous vault, the ATA-centered model had an MAE of 181.3 µm (95% CI, 163.0-201.1), 17.7 µm lower than the WTW-centered model (95% CI, 4.1-31.7). Adding the expanded ATA variables produced little further improvement. The ATA-centered model also showed good discrimination for low vault (AUC, 0.852), although only 18 patients had this outcome. In a separate paired one-eye analysis, the median within-selection ATA-minus-WTW AUC difference for high vault was 0.049. CONCLUSION: ATA-based models improved prediction of both high and continuous 1-week ICL vault compared with otherwise matched WTW-based models. When an ICL size has already been selected, ATA-based prediction may help identify eyes that warrant closer review of biometric measurements and the proposed sizing plan.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A multi-task Bayesian Hierarchical Gated Transformer for predicting postoperative vault after Implantable Collamer Lens implantationDiscover Applied Sciences · 2026
- Retrospective Validation of an AI Based Tool for Vault Prediction After Implantable Collamer Lens Surgery for High Myopia.Clinical ophthalmology (Auckland, N.Z.) · 2026
- Research on a New Model for Predicting Vault After Implantable Collamer Lens (ICL) Based on Structural Parameters of the Posterior Chamber.Journal of ophthalmology · 2026
- Biometric and ICL-related risk factors associated with suboptimal vault with implantable collamer lenses.Frontiers in medicine · 2026
- Multicenter evaluation of AI-based intraocular lens formulas and interpretable machine learning for cataract refractive predictionScientific Reports · 2026
- Development and Clinical Evaluation of an Anterior Chamber Angle-Based Lens Sizing Method for Implantable Collamer Lens Surgery.Clinical ophthalmology (Auckland, N.Z.) · 2026