Journal of ultrasound

Reference values for liver and spleen stiffness, viscosity, attenuation, and shear-wave speed in healthy adults.

Andrea Boccatonda, Carlotta Bianchi, Silvia Vecchio, Sofia Bakken, Alice Brighenti, Carla Serra

Diagnostic and Therapeutic Interventional Ultrasound Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico Sant'Orsola-Malpighi, via Massarenti n 9, 40138, Bologna, Italy. andrea.boccatonda2@unibo.it. · Diagnostic and Therapeutic Interventional Ultrasound Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico Sant'Orsola-Malpighi, via Massarenti n 9, 40138, Bologna, Italy.

Observational

Key points

From the paper's conclusion
  • Simultaneous multiparametric ultrasound provides a highly reproducible quantitative assessment of liver and spleen mechanical and acoustic properties under standardized acquisition conditions. The preliminary reference values reported in this study are platform-specific and should not be directly extrapolated to other ultrasound systems. Larger multicenter and cross-platform validation studies are warranted.

Abstract

PURPOSE: To establish preliminary, platform-specific reference values for simultaneously acquired multiparametric ultrasound measurements of the liver and spleen in healthy adults, assess interobserver reproducibility, and explore their physiological determinants. METHODS: In this prospective study, 60 healthy adults underwent standardized liver and spleen ultrasound after ≥ 6 h fasting. Two independent operators performed 10 consecutive acquisitions using a multiparametric ultrasound approach providing simultaneous measurements of stiffness, viscosity, attenuation, and shear-wave speed (Cs). Reference distributions and 95th percentiles were estimated using a percentile-based approach. Interobserver reproducibility was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Associations with demographic, anthropometric, morphologic, and portal Doppler characteristics were explored. RESULTS: Median liver stiffness, viscosity, attenuation, and Cs were 5.58 kPa, 1.04 Pa · s, 0.51 dB/cm/MHz, and 1.34 m/s, respectively; corresponding 95th percentiles were 8.25 kPa, 1.40 Pa · s, 0.640 dB/cm/MHz, and 1.64 m/s. Median spleen values were 18.41 kPa, 2.30 Pa · s, 0.67 dB/cm/MHz, and 2.41 m/s, with 95th percentiles of 23.75 kPa, 2.93 Pa · s, 0.99 dB/cm/MHz, and 2.69 m/s, respectively. BMI was independently associated with liver stiffness and Cs, whereas liver viscosity was associated with age, BMI, and sex. Splenic mechanical parameters were largely independent of demographic and anthropometric characteristics. Spleen attenuation was inversely associated with spleen size. CONCLUSION: Simultaneous multiparametric ultrasound provides a highly reproducible quantitative assessment of liver and spleen mechanical and acoustic properties under standardized acquisition conditions. The preliminary reference values reported in this study are platform-specific and should not be directly extrapolated to other ultrasound systems. Larger multicenter and cross-platform validation studies are warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers