Combined ultrasonographic and clinical assessment of bioimpedance-defined volume status in dialysis patients: a diagnostic accuracy study.
Gökhan Öztürk, İlhan Kurultak, Fethi Emre Ustabaşıoğlu, Sedat Üstündağ
Division of Medical Oncology, Department of Internal Medicine, Trakya University Faculty of Medicine, Edirne, Turkey. gokymd@gmail.com. · Division of Nephrology, Department of Internal Medicine, Trakya University Faculty of Medicine, Edirne, Turkey.
Key points
From the paper's conclusion- The combined use of bedside lung ultrasound-derived B-lines with pretibial edema assessment demonstrates good discriminatory performance for identifying clinically relevant overhydration in dialysis patients and may serve as a practical, noninvasive adjunct to bioimpedance analysis, particularly in settings where BIS is not readily available.
Abstract
BACKGROUND: Accurate assessment of volume status in dialysis patients remains challenging, and no single method is universally accepted. This study aimed to evaluate the combined diagnostic performance of lung ultrasonography and physical examination for predicting bioimpedance spectroscopy (BIS)-defined volume overload. METHODS: In this cross-sectional study, 44 dialysis patients underwent clinical evaluation, lung ultrasonography, inferior vena cava assessment, and BIS measurement. Clinically significant volume overload was defined as BIS-derived overhydration ≥ 2500 mL. The diagnostic performance of B-line count and pretibial edema was assessed using logistic regression and receiver-operating characteristic (ROC) analysis. RESULTS: Volume overload was significantly associated with B-line count and pretibial edema. In multivariable analysis, both parameters remained independent predictors of volume status, with B-line count demonstrating the strongest individual predictive performance. The addition of pretibial edema significantly improved overall model fit and provided incremental diagnostic value beyond B-line count alone. The combined model showed good discriminative ability for identifying hypervolemic dialysis patients, with an area under the curve (AUC) of 0.941 (95% CI 0.879-1.000). CONCLUSION: The combined use of bedside lung ultrasound-derived B-lines with pretibial edema assessment demonstrates good discriminatory performance for identifying clinically relevant overhydration in dialysis patients and may serve as a practical, noninvasive adjunct to bioimpedance analysis, particularly in settings where BIS is not readily available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Discordance between extracellular volume and hemodynamic congestion in hemodialysis: A pilot multiparametric study.Nefrologia · 2026
- Physiological discordance between clinical examination, bioimpedance spectroscopy, and lung ultrasound in maintenance hemodialysis patients without heart failure.Frontiers in nephrology · 2026
- Comparative Assessment of Pre-Dialysis Fluid Status Using Clinical, Lung, and IVC Ultrasound Methods with Bioimpedance Spectroscopy as Reference Standard in Hemodialysis PatientsKidney and Dialysis · 2026
- Feedback-controlled ultrafiltration as a useful tool for the diagnosis of volume status assessment in dialysis patients: a pilot study.Journal of nephrology · 2026
- Ultrasound-guided haemodynamic profiling in haemodialysis patients: a single-centre prospective observational study protocol.Frontiers in nephrology · 2026
- Concordance of a Laboratory-Data Integrated Fluid Targeting Algorithm with Bioimpedance-Derived Volume Measures in Maintenance Hemodialysis.Kidney360 · 2026