A conical-reflector scintillation device for 3-dimensional measurement of radiotherapy beams: a feasibility study.
Benjamin Broadhead, Scott Crowe, Tanya Kairn, Samuel Peet, Andrew Fielding, Timothy Moroney, Prabhakar Ramachandran, Jamie Trapp
School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD, Australia. ben.broadhead@hdr.qut.edu.au. · Radiation Oncology, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.
Key points
From the paper's conclusion- This proof-of-concept study demonstrated that reflection arc geometry and intensity in a single 2D image provided sufficient information to infer spatial beam position, lateral field width, and penumbra characteristics for static irradiations.
Abstract
This study presents a novel optical dosimetry system designed to support three-dimensional characterisation of radiotherapy beams using a single-camera imaging geometry. The system combines a large-volume cylindrical plastic scintillator with a conical reflector, enabling scintillation light emitted during beam irradiation to be captured as both direct emission and secondary reflection arcs using a single camera. These reflected signals encode spatial information about the beam's position, size, and intensity, forming the basis for extracting clinically relevant parameters such as beam geometry and intensity from a single 2D image. Controlled experiments using a 6 MV photon beam investigated the system's response to changes in beam position, lateral width, and penumbra shape. Analysis of reflection arc geometry and intensity demonstrated strong linear correlations between beam position and arc radius over lateral and longitudinal shifts of up to 60 mm and 70 mm respectively, and a clear non-linear relationship between the average arc intensity and lateral beam field widths between 10 and 80 mm. Additionally, penumbra widths derived from reflection arc profiles were linearly proportional to those measured directly in the scintillator, with the arc penumbra approximately times wider than the underlying scintillator observed beam penumbra. This proof-of-concept study demonstrated that reflection arc geometry and intensity in a single 2D image provided sufficient information to infer spatial beam position, lateral field width, and penumbra characteristics for static irradiations. The simplicity, symmetry, and static design of the system support future development towards volumetric beam reconstruction and, through sequential image acquisition, potentially time-resolved treatment verification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR BrachytherapyarXiv · 2026
- Dosimetric assessment of radiation fields up to 5 × 5 cm 2 and architectural optimization of a diode-based 3D Detector for radiotherapyJournal of Physics: Conference Series · 2026
- Design optimization and validation of a DOI-based directional radiation monitoring system for real-time nuclide identification and source localizationNuclear Engineering and Technology · 2026
- Detective quantum efficiency (DQE)-oriented design of a transparent scintillator tandem x-ray/optical microscope for photon-starved 7.2-keV radiography at the National Ignition Facility (NIF).The Review of scientific instruments · 2026
- Commissioning and clinical positioning assessment of a novel surface-guided radiation therapy (SGRT) system at a C-Arm linear accelerator.Journal of applied clinical medical physics · 2026
- Multi-Parameter Optimization and Imaging Performance Evaluation of a 16 × 1 Ce:GAGG Linear Scintillator Detector: A Monte Carlo Simulation Study.Materials (Basel, Switzerland) · 2026