TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation.
Alessandra Zerillo, Stefano Cannata, Diego Bellavia, Daniele Ciriello, Simone Manini, Salvatore Pasta, Caterina Gandolfo
Department of Research, IRCCS-ISMETT, Palermo, Italy. · Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT, Palermo, Italy.
Key points
From the paper's conclusion- These findings support the technical feasibility and promising initial performance of TAVI-TEC.
Abstract
Computed tomography angiography (CTA) is crucial for preprocedural TAVI planning, providing the anatomical information required for prosthesis sizing and vascular access assessment. As the volume of TAVI procedure increases, improving efficiency and standardizing annotations is becoming essential in clinical practice. This study presents TAVI-TEC, a fully automated artificial intelligence-based framework integrated into a web-based DICOM viewer for routine preoperative TAVI planning. Pre-procedural CTA scans from patients undergoing TAVI with SAPIEN 3 Ultra (S3U) prostheses were processed using a fully automated pipeline. Deep learning-based segmentation of cardiovascular structures, calcification detection, centerline extraction, landmark identification, and annular plane definition was implemented to quantify key annular and aortic root measurements and color-coded maps of lumen reduction and vessel diameter for vascular access. A multilayer perceptron classifier was trained to predict prosthesis size prior to the TAVI procedure. Results revealed that TAVI-TEC enabled pre-procedural measurements in approximately 2-6 min. Strong agreement with clinician-derived measurements was observed for annular area (coefficient of concordance, CCC = 0.934; interclass correlation coefficient, ICC = 0.935; R² = 0.881) and perimeter (CCC = 0.909; ICC = 0.909; R² = 0.854). The valve-size prediction model achieved a classification accuracy of 77.1% (95% CI: 70.1-83.9%) with the clinically selected and implanted valve size, with most discordances occurring between adjacent prosthesis sizes. These findings support the technical feasibility and promising initial performance of TAVI-TEC. Prospective multicenter and external validation, including additional valve platforms, will be required before routine clinical implementation and before its effects on operator variability and clinical workflow can be established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of fully-automated AI based CT-analysis on pre-procedural TAVI planning.Clinical research in cardiology : official journal of the German Cardiac Society · 2026
- Applications of Artificial Intelligence in Transcatheter Aortic Valve Replacement: A Review of the LiteratureLife · 2025
- Autoregressive prediction of hemodynamics before TAVR in latent space with pretrained video autoencodersCurrent Directions in Biomedical Engineering · 2026
- AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.Tomography (Ann Arbor, Mich.) · 2026
- Survival Prediction of TAVI Patients Using End-to-End Deep Image Regression on Whole-Body CT.Studies in health technology and informatics · 2026
- Multimodal CT-echocardiographic score for preprocedural prediction of permanent pacemaker implantation after transcatheter aortic valve replacementEuropean Heart Journal · 2026