Impact of fully-automated AI based CT-analysis on pre-procedural TAVI planning.
Mani Arsalan, Tami Duske, Hanna Schneider, Alexander R Tamm, Philipp Christian Seppelt, Martin Geyer, Kerstin Piayda, Ralph Stephan von Bardeleben,
Department of Cardiac Surgery, University Hospital of the Goethe University, Theodor-Stern-Kai 7, 60590, Frankfurt/Main, Germany. mani.arsalan@gmail.com. · Department of Cardiology, University Medical Centre Mainz, Mainz, Germany.
Key points
From the paper's conclusion- In this retrospective study, fully automated AI-based CT analysis demonstrated excellent agreement with conventional semi-automated measurements of the aortic annulus. Nevertheless, similar to established planning workflows, expert interpretation remains crucial to integrate the broader anatomical and clinical context required for optimal prosthesis size selection.
Abstract
BACKGROUND: Accurate pre-procedural computed tomography (CT) analysis is essential for optimal valve sizing and clinical outcomes in transcatheter aortic valve implantation (TAVI). Recently, fully automated, artificial intelligence (AI)-based CT analysis platforms have been developed to simplify and standardize this process. AIMS: The aim of the study was to investigate the clinical impact of this new analysis method on the selection of valve prosthesis size. METHODS: Overall, 247 patients with symptomatic severe aortic stenosis were enrolled. Patients underwent TAVI procedures at two different heart centres. The pre-procedural datasets were analysed by a standard TAVI CT-analysis software (3M, Pie Medical Imaging BV, The Netherlands) and a fully-automated CT-analysis-platform employing a deep-learning based algorithm. Key annular measurements and simulated prosthesis size selection were compared between both methods. RESULTS: The mean aortic annulus diameter was 24.5 ± 2.3 mm (3mensio) and 24.4 ± 2.4 mm (AI), respectively, with a mean absolute error (MAE) of 0.6 mm and mean absolute percentage error (MAPE) of 2.6%. Annulus perimeter (76.9 ± 7.0 mm vs. 74.6 ± 7.3 mm; MAE: 2.0 mm; MAPE: 2.6%) and annulus area (458.4 ± 87.2 mm2 vs. 440.9 ± 85.6 mm2; MAE: 21.2 mm2; MAPE: 4.6%) showed excellent correlation (intraclass correlation coefficients > 0.95). Prosthesis size selection simulated on the basis of AI-derived measurements would have differed from the implanted size in 21% of patients, compared with 14% when using the semi-automated method. CONCLUSIONS: In this retrospective study, fully automated AI-based CT analysis demonstrated excellent agreement with conventional semi-automated measurements of the aortic annulus. Nevertheless, similar to established planning workflows, expert interpretation remains crucial to integrate the broader anatomical and clinical context required for optimal prosthesis size selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- TAVI-TEC: an AI-based tool for procedural planning of transcatheter aortic valve implantation.Cardiovascular intervention and therapeutics · 2026
- AI-Driven CT Analysis for Aortic Disease: A Task-Based Systematic Review of Segmentation, Measurement, and Detection Applications.Tomography (Ann Arbor, Mich.) · 2026
- Fully automated assessment of post-TEVAR follow-up CT scan using Deep Learning-Based Segmentation.Annals of vascular surgery · 2026
- Comparing Manual and Semi-Automatic AI-Based Methods for Aortic Landing Zone Assessment for Endovascular Treatment of Thoracic Aortic Aneurysm.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- Real-life clinical validation of artificial intelligence-assisted echocardiography for aortic root and left ventricular outflow tract measurements against human readers and cardiac magnetic resonance.European heart journal. Digital health · 2026
- Comparative analysis of TAVI planning software: implications for prosthesis sizing and clinical outcomeEuropean Heart Journal · 2026