Clinical journal of gastroenterology

Does computer-aided detection still add value in high-performing colonoscopy? A systematic review and meta-analysis of randomized trials.

Mohd Diya Masmoum, Yamen Shayah, Ghali Masmoum, Jabr Asmew

Internal Medicine, Toronto Metropolitan University, Toronto, Ontario, Canada. diyagomass@gmail.com. · Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, Pennsylvania, USA.

Meta-analysis

Key points

From the paper's conclusion
  • In high-detection colonoscopy settings, CADe substantially reduces adenoma misses and improves overall adenoma and sessile serrated lesion detection, demonstrating benefits beyond advanced neoplasia detection. Although a statistically significant improvement in advanced adenoma detection was not demonstrated, the potential long-term clinical benefits of improved lesion recognition remain uncertain.

Abstract

BACKGROUND: Computer-aided detection (CADe) improves adenoma detection in broad randomized-trial populations, but its incremental value may diminish when baseline colonoscopy performance is already high. We evaluated whether CADe improves advanced neoplasia detection in contemporary high-detection practice. METHODS: PubMed/MEDLINE, Embase, CENTRAL, Scopus, Google Scholar, ClinicalTrials.gov, and WHO ICTRP were searched from inception through September 2026. Randomized trials were eligible when control-arm adenoma detection rate (ADR) was at least 35%; FIT-only trials were analyzed separately. Advanced adenoma detection rate (AADR) and advanced colorectal neoplasia detection rate (ACNDR) were primary outcomes. Random-effects models used restricted maximum likelihood with modified Hartung-Knapp inference. Risk of bias was assessed using RoB 2 and certainty using GRADE. The protocol was prospectively registered in PROSPERO (CRD420261495680). No external funding was received. RESULTS: Forty-eight unique randomized trial families were included. In routine high-detection trials, no statistically significant improvement in AADR was demonstrated (17 trials; RR, 1.018; 95% CI, 0.921-1.125; I² = 0%). CADe reduced whole-colon tandem adenoma miss rate (6 trials; RR, 0.473; 95% CI, 0.363-0.618) and increased overall ADR (28 trials; RR, 1.137; 95% CI, 1.082-1.194). The ADR effect was not clear when control ADR was at least 50% (RR, 1.039; 95% CI, 0.964-1.120). Sessile serrated lesion detection increased (RR, 1.284; 95% CI, 1.125-1.465). Advanced-neoplasia estimates were limited by sparse compatible reporting. CONCLUSIONS: In high-detection colonoscopy settings, CADe substantially reduces adenoma misses and improves overall adenoma and sessile serrated lesion detection, demonstrating benefits beyond advanced neoplasia detection. Although a statistically significant improvement in advanced adenoma detection was not demonstrated, the potential long-term clinical benefits of improved lesion recognition remain uncertain. PROSPERO REGISTRATION: CRD420261495680.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Does computer-aided detection still add value in high-performing colonoscopy? A systematic review and meta-analysis of randomized trials — Science Skim