Artificial intelligence-based computer-aided detection systems for adenomas during colonoscopy: a systematic review and Bayesian network meta-analysis.
Zhenjia Fan, Danyan Li, Jixiang Liu, Yudi Zhuo, Shengsheng Zhang
Digestive Disease Center, Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- Compared with CC, the CADe system significantly improved ADR. However, given the limited direct comparative evidence and the star-shaped network, the results, especially the differences among systems, should be interpreted cautiously.
Abstract
BACKGROUND AND AIMS: Artificial intelligence-based computer-aided detection (CADe) systems have been developed to enhance the adenoma detection rate (ADR) during colonoscopy, but their performance is unknown. We primarily aimed to compare the effectiveness of each CADe system with conventional colonoscopy (CC). As a secondary objective, we performed an exploratory comparison among different CADe systems. METHODS: A systematic literature search of 6 databases was conducted to find randomized controlled trials (RCTs) evaluating the use of CADe systems during colonoscopy. A Bayesian network meta-analysis was performed on the included studies using R 4.5.2 software. The primary outcome was ADR. RESULTS: A total of 21 RCTs involving 19,006 participants were included. Nine CADe systems were compared. For ADR based on modified intention-to-treat (ADR-mITT), DEEP2 (RR 1.37; 95% CrI 1.07-1.76), Eagle-Eye (RR 1.19; 95% CrI 1.02-1.38), and ENDO-AID (RR 1.27; 95% CrI 1.13-1.41) were significantly higher than CC. For ADR based on intention-to-treat (ADR-ITT), AQCS was significantly higher than CC. For adenoma per colonoscopy (APC) and diminutive adenoma detection rate (DADR), ENDO-AID showed significant advantages over CC. However, no significant differences were observed among CADe systems in terms of high-risk lesion detection rate (including advanced adenoma detection rate [AADR] and sessile serrated lesion detection rate [SDR]) or withdrawal time (WT). CONCLUSION: Compared with CC, the CADe system significantly improved ADR. However, given the limited direct comparative evidence and the star-shaped network, the results, especially the differences among systems, should be interpreted cautiously. SYSTEMATIC REVIEW REGISTRATION: https://www.crd.york.ac.uk/PROSPERO/view/CRD420261290518, identifier: CRD420261290518.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Efficacy Of Different Computer-Aided Detection Products in Colonoscopy: A Network Meta-Analysis Of Randomized Controlled Trials.Endoscopy · 2026
- Computer-aided polyp detection and characterisation systems to support colonoscopy: a systematic review with results stratified by each individual artificial intelligence system.BMJ digital health & AI · 2026
- Artificial Intelligence-Assisted Colonoscopy Improves Adenoma Detection by Trainee and Less-Experienced Endoscopists: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Gastroenterology research · 2026
- Artificial intelligence in colonoscopy for colorectal cancer prevention: a comprehensive narrative review of technology, evidence and clinical implementation.Translational gastroenterology and hepatology · 2026
- Efficacy of artificial intelligence in detecting precancerous lesions among a colorectal cancer screening population undergoing surveillance colonoscopies in Italy: a randomized control trial (GENIAL-CO Follow-Up study).Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2026
- Does computer-aided detection still add value in high-performing colonoscopy? A systematic review and meta-analysis of randomized trials.Clinical journal of gastroenterology · 2026