科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver2026-08-13

Pragmatic real-world evaluation of computer-aided detection in colonoscopy: A within-endoscopist comparative study.

Carlos Bernardes, Manuel Rocha, Jaime Rodrigues, Pedro Bastos, Raquel Ortigão, Ricardo Veloso, Teresa Moreira, Liliana Rafael, Cláudia Lourenço, Márcia Pinto, Lígia Prado, Pedro Pimentel-Nunes

一句话结论 · In one sentence

In a pragmatic real-world setting, CADe improved detection of colorectal neoplasia. This within-endoscopist design provides a balanced estimate of effectiveness by minimising behavioural bias affecting both trial and real-world studies.

原始摘要(英文原文)· Original abstract
BACKGROUND: Computer-aided detection (CADe) improves adenoma detection rate (ADR) in randomised trials; however, translation into routine practice remains uncertain, with real-world studies showing inconsistent results. AIMS: To evaluate CADe in a pragmatic multicentre setting using a within-endoscopist design, with endoscopists serving as their own comparators under routine clinical conditions. METHODS: Pragmatic multicentre observational study analysing prospectively recorded data from 13 units. Six endoscopists performed procedures in a unit with routine CADe use and in units without CADe, enabling within-operator comparisons under naturalistic conditions. The primary outcome was ADR. Secondary outcomes included combined adenoma plus clinically significant serrated polyp detection rate (A+CSSPDR) and additional polyp-related metrics. RESULTS: Of 3161 colonoscopies, 2973 were analysed (947 CADe; 2026 non-CADe). ADR was higher with CADe (34.4%vs 30.7%; p = 0.042). A+CSSPDR was also higher (40.3%vs 35.8%; p = 0.018), with consistent improvements across other metrics. In multivariable analysis, CADe remained independently associated with higher ADR (aOR 1.31, 95%CI 1.11-1.55; p = 0.002) and A+CSSPDR (aOR 1.33, 95%CI 1.13-1.56; p = 0.001), with attenuation after adjustment for endoscopist. CONCLUSION: In a pragmatic real-world setting, CADe improved detection of colorectal neoplasia. This within-endoscopist design provides a balanced estimate of effectiveness by minimising behavioural bias affecting both trial and real-world studies.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Pragmatic real-world evaluation of computer-aided detection in colonoscopy: A within-endoscopist comparative study. — 科研速览 Science Skim