Manual CBCT registration by Japanese radiological technologists: agreement with a clinical reference position and exploratory associations with professional experience.
Hidekazu Suzuki, Tomoki Koide, Koji Ueda, Yosuke Miyasaka, Naoki Sano, Yoshihito Aikawa, Hironobu Tomita
Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan. suzuki.hidekazu.ic@teikyo-u.ac.jp. · Department of Radiology, University of Yamanashi Hospital, Chuo, Yamanashi, Japan.
Key points
From the paper's conclusion- Overall professional experience was negatively associated with both outcomes (ρ = -0.895, p = 0.002; ρ = -0.929, p < 0.001).
Abstract
In this retrospective observer study, nine Japanese radiological technologists each performed fully manual offline cone-beam CT registration for 29 cases (261 registrations), blinded to the clinical reference positions adopted by radiation oncologists. Agreement was assessed by three-dimensional deviation; observer-level standard deviation across cases represented between-case variability. Associations with radiotherapy and overall professional experience were explored using Spearman correlations with exact permutation tests and leave-one-observer-out analyses. Mean deviation was 1.41 ± 1.16 mm (median, 1.06 mm); 74.7% of registrations were within 2 mm. Radiotherapy experience was negatively associated with observer-level mean deviation (ρ = -0.820, p = 0.010), but its association with between-case variability was weaker (ρ = -0.502, p = 0.171). Overall professional experience was negatively associated with both outcomes (ρ = -0.895, p = 0.002; ρ = -0.929, p < 0.001). These exploratory associations do not establish independent or causal effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible - a paired in vitro method-comparison study.International journal of implant dentistry · 2026
- ConRef: Auditing Reference Reliability in 2D/3D Registration BenchmarksarXiv · 2026
- Evaluation of registration accuracy using short-arc cone-beam computed tomography for image-guided radiotherapy in breast cancer.Journal of applied clinical medical physics · 2026
- Use of CBCT in dental implantology: a cross-sectional survey among postgraduate students in Italy.BMC oral health · 2026
- Diagnostic Reference Levels for Dental Cone Beam Computed Tomography: A Critical Appraisal of Global Progress and Remaining Gaps.Cureus · 2026
- Patient Centring in CT: An International Survey of Clinical Practice and Future Directions.Journal of medical radiation sciences · 2026