Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible - a paired in vitro method-comparison study.
Georg Hoene, Shabnam Shahpasand, Felix Karl Waffenschmidt, Frederik Holdorf, Robert Stünkel, Alexander-Nicolai Zeller, Philipp Kauffmann
Clinic for Oral and Maxillofacial Surgery, University Medical Center Goettingen, Robert-Koch-Strasse 40, D-37075, Goettingen, Germany. Georg.Hoene@med.uni-goettingen.de. · Department of Phoniatrics and Pediatric Audiology, University Hospital Muenster, Muenster, Germany.
Key points
From the paper's conclusion- Conclusions In this in vitro setting, IOS- and CBCT-based implant assessment in the posterior mandible showed good agreement with small overall differences, and IOS demonstrated lower within-method variability than CBCT.
Abstract
BACKGROUND: Three-dimensional postoperative implant assessment is increasingly performed using intraoral scan (IOS) superimposition as a radiation-free alternative to cone-beam computed tomography (CBCT). However, it remains unclear to what extent IOS- and CBCT-based measurements agree and how reproducibility changes across posterior mandibular configurations. METHODS: In this paired in vitro method-comparison study, based on the experimental platform of a previous study, 60 implants placed at Fédération Dentaire Internationale (FDI) positions 35, 36, 45, 46 and 47 in bounded edentulous spaces (BES) and distal extension situations (DE) underwent three IOS-based and three CBCT-based postoperative assessments relative to the virtual plan using the Treatment Evaluation Tool of the planning software. Angular, mesiodistal, buccolingual, apico-coronal, and three-dimensional (3D) deviations at implant base and apex were recorded, resulting in 180 paired measurements. Agreement was assessed by Bland-Altman analysis, and within-method reproducibility by the within-implant standard deviation (Sw). IOS variability was additionally separated into within-scan and between-scan components. Non-parametric analyses were used for comparisons by indication and FDI position. RESULTS: Mean absolute IOS-CBCT differences were 0.73° ± 0.55° for angular deviation, 0.22 ± 0.20 mm for the 3D base offset and 0.26 ± 0.22 mm for the 3D apical offset. Bland-Altman bias (CBCT - IOS) was small (- 0.35°; -0.05 mm; -0.07 mm) with 95% limits of agreement of [- 2.01°; +1.31°], [- 0.62; +0.53] mm and [- 0.73; +0.58] mm. Within-method reproducibility was superior for IOS in 8 of 9 parameters (e.g., Sw 0.20° vs. 0.55° for the angle), and IOS variability was dominated by scan-to-scan rather than within-scan re-evaluation. Discrepancies were larger in DE than in BES sites in 7 of 9 parameters (all p < 0.001 for the principal apical and buccolingual components) and were larger at position 47 than at position 35 (3D base p = 0.004; 3D apex p = 0.011). CONCLUSIONS: In this in vitro setting, IOS- and CBCT-based implant assessment in the posterior mandible showed good agreement with small overall differences, and IOS demonstrated lower within-method variability than CBCT. IOS-based superimposition may therefore serve as a radiation-free complement to CBCT for the postoperative evaluation of single implants in bounded posterior sites. Agreement decreased in distal extension situations and at more distal positions; in these configurations, and whenever clinical decisions depend on sub-millimeter or sub-degree precision, CBCT remains the reference technique. Confirmation in vivo is required before routine clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Limitations of RMS error in evaluating intraoral scanner accuracy: Comparison with linear and angular distortions from an enhanced metrology protocol.The Journal of prosthetic dentistry · 2026
- Effect of 3D superimposition software on intraoral scanner accuracy and monitoring outcome.Clinical oral investigations · 2026
- Digitization of a Single Tissue-Level Implant Without Scan Body - A Feasibility Study.Journal of dentistry · 2026
- Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study.European journal of dentistry · 2026
- Relative accuracy of intraoral photogrammetry and intraoral scanning with conventional scan-body for full-arch implants.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- 3D superimposition of cone-beam computed tomography and intraoral scan models for forensic identification: Development and validation of a quantitative analysis method.Forensic science international · 2026